protection areas in accordance
with din Vde 0100-701

Electrical installation:

Installation of the connection wiring including the potential equalisation (potential equalisation
n
rail is fitted to the frame) of the whirlpool must be done in accordance with the provisions of
your local electricity supplier and observing DIN VDE 0100-701. The connections must be made
by a licensed electrician
The protected areas must be precisely adhered to
n
Parts of the device which contain live parts – excluding parts with protected low voltages up to
n
12V – must be inaccessible for persons using the bath.
The connection may only be made in zone 3, outside the protected areas 0 to 2
n
Electrical connections:
Caution: All assembly and disassembly work on the whirlpool may only be done when isolated
n
from the mains supply and in a dust-free condition!
The complete system must be connected through a residual current device (RCD breaker) with
n
a rated residual current of not more than 30 mA.
The whole system must also be permanently connected to the mains via an allpole mains
n
isolation switch meeting monitoring category III, which gives a full disconnection, via
permanently fixed wires, fused at 16A.
Switch panel connection lead
n
Bathtub: F3Gx1.5 (NYMHY 3 x 1.5 mm
n
The whirlpool must be turned off when not in use or in the case of serv