9
Accuracy Check
The accuracy of the laser beam should be checked regularly. This requires a free measuring length
of 10 m. The check takes place in two steps.
Step 1
•
Position the CrossLiner 2 as shown in the figure to the
right.
•
Switch on the horizontal laser line using the "H" switch.
•
Mark point A on the laser line.
•
Rotate the CrossLiner 2 through 180° and mark point B
on the laser line.
Step 2
•
Position the CrossLiner 2 opposite as shown in the
diagram to the right.
•
Align the CrossLiner 2 with marking B.
•
Rotate the CrossLiner 2 through 180°.
•
Measure the vertical distance H between marking A and
laser line C*.
•
If the measured distance H between marking A and
laser line C* is < 6 mm, the CrossLiner 2 is within the
tolerance range.
* The laser line C may be above or below marking A.
Note: If the vertical measured distance H between marking A and the laser line C is outside the
tolerance range, the CrossLiner 2 must be examined by an authorised customer service agent or
by NEDO.
10
Troubleshooting
Note:
If the errors cannot be rectified using one of the listed remedies, the CrossLiner 2 must be exam-
ined by an authorised customer service agent or by NEDO.
Error
No laser line is projected after
pressing switch H and IV.
No self-levelling,
laser beams/LED displays
flashing
CrossLiner 2 Operating Instructions
All manuals and user guides at all-guides.com
Cause
No power supply
Inadequate power supply
Compensator is locked
Unit outside the self-levelling
range.
16
A
~0,5 m
10 m
Remedy
Insert batteries
Replace batteries
Release compensator
Realign the CrossLiner 2
within the self-levelling range of
3°.
EN
B