CREE
IMPORTANT SAFEGUARDS
WARNING - Risk of fire or electric shock. Disconnect power at fuse or
circuit breaker before installing or servicing.
READ AND FOLLOW ALL SAFETY
INSTRUCTIONS
1.
WARNING - Risk of fire or electric shock. LED Retrofit Kit installation
requires knowledge of luminaires electrical systems. If not quaified,
do not attempt installation. Contact a qualified electrician.
2.
WARNING - To prevent wiring damage or abrasion, do not expose
wiring to edges of sheet metal or other sharp objects.
3.
WARNING- Risk of fire or electric shock. Install this kit only in the
luminaires that have the construction features and dimensions
shown in the photographs and/or drawings where the input rating of
the retrofit kit does not exceed the input rating of the luminaire.
4.
SUITABLE FOR TYPE IC LUMINAIRES.
5.
It may be necessary to remove a socket mounting plate for adequate
clearance.
6.
Each lampholder shall be installed only in its intended manner and
orientation.
7.
Suitable for Wet Locations.
8.
Min. temperature rating of -25
9.
Do not make or alter any open holes in an enclosure of wiring or
electrical components during kit installation.
10.
SUITABLE FOR INSTALLATION IN A RECESSED CAN WITH
A MAXIMUM OF EIGHT (8) No. 12 AWG THROUGH-BRANCH
CIRCUIT CONDUCTORS SUITABLE FOR 75
11.
WARNING-THIS RETROFIT KIT IS ACCEPTED AS A COMPONENT
OF A LUMINAIRE WHERE THE SUITABILITY OF THE COMBINATION
SHALL BE DETERMINED BY AUTHORITIES HAVING JURISDICTION.
MIN. LAMP COMPARTMENT DIMENSIONS
5.5 inch/139.?mm (DIA) x 5.5 inch/139.?mm (H).
This device is not intended for use with emergency exit fixtures or
12.
emergency exit lights.
SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE
•
TO INSTALL:
Flip Clip
STEP 1:
Careful ly rotate the ··Flip Clips·· clockwise
until the clips a re fully-dep loyed. See
STEP 2:
POWER IS TURNED OFF
Make sure the
the source to the recessed can.
1 of 2
°
C.
°
C MIN.
NOTE:
For 5" recessed cans, it is
recommended not to rotate the flip clips
into the fully dep loyed position.
Figure 2.
STEP 3:
at
Remove existing trim and bulb, revealing
the existing recessed socket.
STEP 4:
Install "Field Applied Label" into the
recessed can.
6" Recessed LED Downlight
INSTALLATION INSTRUCTIONS-ENGLISH
Package Contents:
Part
Description
6" Retrofit downliaht
A
B
Edison Socket Adapter
•
GU24 Socket Adapter
C
D
Field applied label
Minimum distance
between edge of
fixture and top of
housing or other
obstruction.
7.48 inch
(190mm) (139.7mm)
RECESSED HOUSING COMPATIBILITY
• Desig ned to install in standard 6in recessed downlight
housings.
• Compatible with most dimmers when used with multiple
fixtures. Consult lighting.cree.com for a
compatibility chart.
• Compatibilit y of housing s may be determined b y
measurement of the housin g as detailed in the d rawing
above(Figure 1).
STEP 5:
FOR EDISON BASE SOCKET INSTALLATION:
Connect Edison socket adapter [par t Bl to
the existing LED adapter attached to the
down light. Then, screw the Edison base
socket into the recessed can Edison socket
by tur ning clockwise.
FOR GU24 SOCKET INSTALLATION:
GU24 socket adapter [par t C) to the existing
LED adapter attached to the downlight.
Then, inser t pins on GU24 base socket into
the recessed can GU24 socket by turning
clockwise until locked.
FOR LED DIRECT CONNECT INSTALLATION:
Connect down light LED adapter attached to
the down light to the LED adapter attached
to the recessed can.
CR6-T Series
Quantity
1
1
1
1
5.5 inch
5.5 inch
(139.7mm)
See Figure 3.
Connect
See Figure 3.
LPN000246