DS06 LOW LEAD CONTENT DIAL SET PRESSURE REGULATING VALVES
Water Capacities
The suitability of a given regulator size is dependent on
the pressure requirements where it will operate. For the
pressure regulator valve size required for a specific
installation, determine the following:
1. Pressure differential between inlet and outlet pres-
sure in pounds per square inch (psi),
2. Capacity in gallons per minute, and
Pressure
Reduced
Regulator Valve
Pressure Falloff
Size
1/2"
6
10
15
20
3/4"
6
10
15
20
1"
6
10
15
20
1-1/4"
6
10
15
20
1-1/2"
6
10
15
20
2"
6
10
15
20
DSO6 Fixture Unit
Flow rates based on submittal sheet DS06, based on
flush tank systems with a 15 psi fall-off defined by
IAPMO/ANSI UPC 1-2009.
Size
I/s
1/2"
0.99
3/4"
1.58
1"
1.77
1-1/4"
2.19
1-1/2"
4.93
2"
6.61
Capacities are based on a 100 psi supply pressure and a
difference of 50 psi or more between the initial supply
pressure and the reduced no-flow pressure.
33-00014EF—08
Table 1. Water Capacities.
25 psi
Flow Capacity
(PSI)
(US gpm)
7.26
10.7
14.27
17.74
11.98
17.17
19.86
21.27
11.18
18.01
25.67
30.69
7.53
20.25
33.02
40.07
29.81
46.14
66.22
77.14
27.34
64.81
82.82
87.66
Table 2.
GPM
Fixture Units
15.72
25.14
28.14
34.87
78.42
105.14
3. Allowable reduced pressure falloff in psi. Given
these variables, use Table 1 to determine the
proper size pressure regulator valve for your appli-
cation.
Example: An installation has 135 psi inlet pressure,
60 psi outlet pressure (75 psi pressure differential). If a
15 gpm capacity is required with only 10 psi falloff
allowable, a 3/4 in. DS06 is required.
Pressure Differential Between Inlet and Outlet
50 psi
Flow Capacity
(US gpm)
8.15
10.66
15.72
19.59
14.44
21.05
25.14
26.42
11.23
18.98
28.14
34.7
6.34
17.88
34.87
44.29
32.27
50.02
78.42
92.29
25.8
97.61
105.14
107.83
Check local water pressures before selection.
Procedure
1. Flush the system clear of sediment or debris.
2. Close the supply valve and downstream isolating
valve (if one is installed).
3. Install the DS06 with the arrow on the body
pointing in the direction of water flow. Install,
21
preferably, in horizontal pipework with filter bowl
40
downwards - vertical installation also possible.
48
The DS06 can be installed directly onto the pipe by using
70
the female NPT threads on each end. If space limitations
restrict turning the DS06, install single- or double-
270
unions.
400
NOTE:
Heat from soldering can damage internal parts
of the DS06. Always solder the tailpieces
separately from the DS06.
2
75 psi
100 psi or more
Flow Capacity
Flow Capacity
(US gpm)
(US gpm)
7.44
6.47
9.69
8.85
14.49
13.96
18.98
18.1
14.53
14.97
25.23
26.33
29.32
32.85
30.42
33.82
9.51
9.11
17.39
16.78
28.71
26.9
36.19
35.05
7.26
7.13
15.15
14
32.63
29.68
46.01
34.61
30.87
26.81
49.89
47.82
86.74
84.14
103.82
109.68
24.48
18.01
78.15
90.09
119.94
129.62
120.95
132.09