koban KPA-11T Manuel D'instructions page 29

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

EN
Function
Frequency
(Auto-ranging)
Input protection: 1000 V AC
Sensitivity:> 20 MV AC
Frequency through test leads when meter is set to AC voltage
Function
Frequency
(Auto-ranging)
Maximum input: 2000 A CA
Sensitivity:> 150 A
Function
Duty cycle
Over rang protection: 600 V rms
Function
Temperature
Sensor: K type banana
Over rang protection: 600 V rms
Function
AC current peak
Frequency behaviour: 50 Hz ~ 60 Hz
Function
Capacitance
Over rang protection: 600 V rms
Function
Diode
Continuity
Over rang protection: 600 V rms
Range
10 Hz to 100 kHz
Range
40 Hz to 1 kHz
Range
0,1 % to 99,9 %
Range
-20 °C to 1000 °C
-4 °F to 1832 °F
Range
400 A
2000 A
Range
4 nF
40 nF
400 nF
4 μF
40 μF
400
μF
Testing condition
Forward DCA is approx. 0,5mA, backward volt-
age is approx. 2V
Open voltage is approx. 0.5V
Accuracy (% of reading + digits)
± 1 % ± 5 dig.
Accuracy (% of reading + digits)
± 1 % ± 5 dig.
Accuracy
(% of reading + digits)
± (1,2 % + 5 dig.)
Accuracy
(% of reading + digits)
± (2 % + 5 °C)
± (3 % + 9 °F)
Accuracy
(% of reading + digits)
± (4 % + 5 dig.)
± (4 % + 5 dig.)
Accuracy
(% of reading + digits)
± (5 % + 30 dig.)
± (5 % + 20 dig.)
± (3,5 % + 10 dig.)
± (5 % + 10 dig.)
± (5 % + 10 dig.)
± (5 % + 10 dig.)
Reading
Forward voltage drops of diode
Buzzer makes a long sound, while
resistance is less than (60 ± 30
KPA-11T
TRMS CLAMP METER
Resolution
0,1 %
Resolution
0,1 °C
0,1 °F
Resolution
100 mA
1 A
Resolution
0,1 nF
1 nF
10 nF
100 nF
1 μF
10 μF
29 / 46
Ω)

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

0767498

Table des Matières