NOTE: If the fan motor plug is connected to the fan housing receptacle, unplug so
the blower assembly can be completely removed.
Screw
Figure 7
NOTE: Wire compartment configuration will be dependent on model.
2.
Run wiring from an approved wall switch carrying the appropriate rating. One
neutral (white), one ground (green or bare copper), and one hot (black lead
connected to the switch). Secure the electrical wires to the housing with an
approved electrical connector. Make sure you leave enough wiring in the box to
make the connection to the fan's receptacle.
3.
From where you have chosen to access the fan's junction box, connect
the White wire from the house to the White wire from the fan's receptacle.
Connect the Black wire from the wall switch to the Black wire from the fan's
receptacle. Connect the ground wire from the house to the Green wire from
the fan's receptacle (Figure 8). Use approved methods for all connections.
Supply from
house
Ground
Figure 8
NOTE: The fan's receptacle wires might need to be pulled outside compartment for
connection. Only pull the three loose wires outside of compartment. Additional wires
will be present.
4.
Carefully tuck wire back inside wire compartment and replace wire
compartment cover securing with the screw that was removed earlier.
SECTION 6
Completing the Installation
1. Use a sealant appropriate for contact with the building materials present and
for the temperature requirements of the installation to prevent air leakage from
unconditioned spaces is recommended. If gaps between unit housing and ceiling
are great, additional material (backing rod, ceiling material) may be required.
NOTE: This fan is rated for direct insulation contact (Type IC) and it is recommended
that this fan be completely covered by insulation in order to reduce heat loss or gain
to unconditioned space.
2.
If the fan's blower assembly was removed during the wiring process, reinstall
the blower by reversing the directions in Section 5 (Wiring), Step 1b.
3a. AKLS MODELS: Plug the fan's quick connect motor cord into the receptacle.
This cord will only fit one way into the receptacle (Figure 9).
Figure 9
A210952008 Rev. F 5-14
Wire Compartment
Cover
White
Hot (Black)
www.airkinglimited.com
3b. AKLS6 MODELS: Plug the fan's 5 pin quick connect motor cord into the
included harness. Plug the 3 pin quick connect harness cord into the
receptacle located on top of the wire compartment. These cords will only fit
one way into the receptacles (Figure 10).
Figure 10
4.
Install the grill by squeezing the two ends of the springs together and
installing them up into the slots on the fan's housing. Push the grill up into
position (Figure 11).
Figure 11
5.
Restore power and test your installation.
SECTION 7
Use and Care
CAUTION:
MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL
BEFORE SERVICING THE UNIT.
Cleaning the Grill: Remove grill and use a mild detergent, such as
1.
dishwashing liquid, and dry with a soft cloth. NEVER USE ANY ABRASIVE PADS
OR SCOURING POWDERS. Completely dry grill before reinstalling. Refer to
instructions in Section 6 Finishing the Installation, to reinstall grill.
2.
Cleaning the Fan Assembly: Wipe all parts with a dry cloth or gently vacuum
the fan. NEVER IMMERSE ELECTRICAL PARTS IN WATER.