Completing The Installation - AirKing E Serie Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Black
Neutral (White)
Green
Figure 11
NOTE: The fan's receptacle wires might need to be pulled outside compartment for connection.
Only pull the five loose wires outside of compartment. Additional wires will be present.
NOTE: Unit must be grounded according to all local and national codes.
6.
Carefully tuck wire back inside wire compartment and replace wire compartment cover
securing with the screw that was removed earlier.
SECTION 6

Completing the Installation

1.
Use a sealant appropriate for contact with the building materials present and for the
temperature requirements of the installation to prevent air leakage from unconditioned
spaces is recommended. If gaps between unit housing and ceiling are great, additional
material (backing rod, ceiling material) may be required.
NOTE: This fan is rated for direct insulation contact (Type IC) and it is recommended that this fan
be completely covered by insulation in order to reduce heat loss or gain to unconditioned space.
2.
If the fan's blower assembly was removed
during the wiring process, reinstall the
blower by reversing the directions in
Section 5 (Wiring), Step 1b.
3a.
STANDARD MODELS: Plug the fan's 2 pin
and 3 pin quick connect motor cords into
the corresponding receptacle located on
the wire compartment cover. These cords
will only fit one way into the receptacles
(Figure 12).
3b.
HUMIDITY SENSING MODELS: Plug the
fan's 2 pin and 3 pin quick connect motor
cords into the corresponding receptacle
located on the wire compartment cover.
Connect the two pin connector from
the humidistat compartment to the two
pin connector from the side of the wire
compartment cover. These cords will only fit
one way into the receptacles (Figure 13).
3c.
MOTION SENSING MODELS: Plug the fan's
2 pin quick connect motor cord into the
receptacle located on the side of the wire
compartment cover. Plug the 3 pin quick connect
motor cord into the shorter end of the included
harness then into the receptacle located on the top
of the wire compartment cover. These cords will
only fit one way into the receptacles (Figure 14).
3d.
HUMIDITY and MOTION SENSING MODELS:
Plug the fan's 2 pin and 3 pin quick connect motor
cords into the corresponding receptacle located
on the wire compartment cover. Connect the two
pin connector from the humidistat compartment
to the two pin connector from the side of the wire
compartment cover. Plug the 3 pin quick
connect motor cord into the shorter end
of the included harness then into the
receptacle located on the top of the wire
compartment cover These cords will only
fit one way into the receptacles (Figure 15).
4.
Install the ceiling mounting flange to cover
any gaps which exist between the housing
and the finished ceiling. Put sealant (not
provided) on inside edge of the ceiling
mounting flange to ensure that the flange
is sealed to the ceiling. Line up the screw
holes in the ceiling mounting flange with
6728035 Rev. R 12-18
Black
Switch
(by others)
Neutral (White)
Ground (Green or Bare)
By others
Figure 12
Figure 13
Figure 14
Figure 15
the screw holes on the inside of the housing and press flange in place so it is tight against
the ceiling. Reinstall ceiling flange mounting screws inside the housing (Figure 16).
Ceiling
Mounting
Flange
Figure 16
NOTE: If the housing is mounted too far or not far enough into the ceiling for the flange to
make a solid connection, loosen the mounting channel and adjust the housing up or down on
the rails. Once in place, fully tighten the mounting channel nuts.
5a.
STANDARD AND HUMIDITY SENSING MODELS: Install the grill by squeezing the two
ends of the springs together and installing them up into the slots on the fan's housing.
Push the grill up into position (Figure 17).
Figure 17
5b.
MOTION SENSING MODELS: Install the grill by squeezing the spring furthest from
the motion sensor together and installing it up into the slot furthest from the wire
compartment on the fan's housing. Attach the 3 pin quick connect from the motion sensor
on the grill to the harness installed in Step 2a. This cord will only fit one way into the
receptacle. Install the other spring in place and push the grill up into position (Figure 18).
Figure 18
6.
Restore power and test your installation.
SECTION 7
Programming the Occupancy Sensor
1a. Setting the Occupancy Time Delay. This will set the amount
of time the fan will continue to operate after the room is
vacated. Locate the motion sensor on the fan's grill and press
the button 2 times. The LED on the sensor will then flash the
number of times to indicate the current setting, this will repeat
3 times:
1 time = 30 seconds
2 times = 2.5 minutes 7 times = 15 minutes
3 times = 5 minutes
4 times = 7.5 minutes 9 times = 20 minutes
5 times = 10 minutes*
www.airkinglimited.com
Screws
Screw Holes
6 times = 12.5 minutes
8 times = 17.5 minutes
* Factory Default