J
CONNECTIONS
J1
ELECTRICAL CONNECTIONS
WARNING
ELECTRIC SHOCK HAZARD
It is the installer's responsibility to carry out the
electrical connections in compliance with the rel-
evant standards.
Comply with the following (not exhaustive) instructions to
ensure a proper electrical connection:
- During installation and maintenance make sure that power supply
to the electric lines has been turned off.
- Use cables with minimum sections, rated voltages and installation
type that are suitable for the characteristics indicated in paragraph
"I - ELECTRICAL DATA" and the installation environment.
- Always make sure that the cover of the terminal strip box is closed
before switching on the power supply, after having checked the
integrity of the seal gaskets that ensure the IP55 protection grade.
- All motors are equipped with a grounding terminal that is to be
connected to the ground line of the electrical system.
PUMP FITTINGS
The pump is fit ed with:
- single-phase motor with 2-mt. (6.5 ft) power cord
- bipolar switch
- capacitor
Wired and installed inside the terminal strip box (see chart)
NOTE
SWITCH
SWITCH
BLACK
BLACK
RED
RED
WHITE
WHITE
M0307
The capacitor characteristics are those indicated on
the pump label. The switch has the only function of
starting/stopping the pump and cannot in any way
replace the main power switch required by the rel-
evant standards.
RED
RED
CAPACITOR
CONDENSADOR
EN
11