(F) TROUBLESHOOTING
PROBLEM
Saddle valve is leaking
Flow rate is very slow
after installation of unit
There are some black
fines in the water
Water appears milky after
installation or after
replacing cartridges
The cartridge came
undone from the head on
it's own
The faucet continues to
drip even after shut-off
Monitor does not light
up when I press the
button
(G) PARTS LIST
PART #
DESCRIPTION
QLV
Replacement filter cartridge
726-0
¼" compression nut
1008-1
Saddle valve complete
1008-3
¼" Delrin sleeve
1011-0
Mounting screw
1050-0
Faucet assembly complete
1050-2
Ceramic disc cartridge for faucet
1603
¼" tube insert
2545
Battery CR2032 (QS1 only)
2713
Head cover insert for QS1
2713-1
Head cover insert for QS1X
2711-1
Monitor assembly (QS1 only)
2723
Cartridge top O-rings
2726
Sump O-ring
2727
QS1 head assembly complete
2727-1
QS1X head assembly complete
2730
¼" tubing
SOLUTION
1) Turn valve handle clockwise to shut water off
2) Make sure that the ferrule and sleeve is correctly installed as per fig 8
3) Fully tighten the compression nut to make sure seal is made
4) Turn valve handle counter clockwise to start water flow
5) If problem persists, call Rainfresh for assistance
You may not have pierced the water pipe fully. Turn valve handle clockwise all
the way until it can go no further to make sure that valve needle has fully pierced
the water pipe.
Call Rainfresh to review installation procedure
Some carbon fines may persist for several days. These are harmless and frequent
running of the unit will clear them more quickly. Running the unit for extended
periods of time will NOT help.
Water can appear milky after a new cartridge is installed because of tiny air
bubbles coming out. These will clear out if you leave the water standing for a few
seconds and are harmless. After a few days of use the bubbles will slowly clear
away.
This may indicate high water pressure or water hammer conditions exceeding
100 psi . You may need to install a pressure regulator (set at 60-70 psi max) and
a water hammer arrestor on the line. Call Rainfresh for further assistance
1) Replace faucet cartridge
2) Call Rainfresh to order ceramic disc cartridge kit (1050-2)
If water is not running through the system and the monitor LED does not light
up, you may need to replace the battery (2545). Call Rainfresh to order
QTY
1
2
1
2
2
1
1
2
1
1
1
1
2
1
1
1
6 ft
1050
2730
1008-1
7