DRINKING WATER SYSTEM
(MODELS QS1, QS1X)
USER MANUAL
We are committed to ensuring that you are totally satisfied.
If you have any problems, don't go back to the store - please contact us !
QUESTIONS
CONTENTS
A. Introduction ................................................. 2
B. Safety Instructions ..................................... 2
C. Technical Specifications........................... 2
D. Installation .................................................... 3
a. Mounting the faucet .................. 3
b. Installing battery ......................... 4
c. Mounting the unit ...................... 4
d. Connecting the faucet............... 4
e. Installing supply valve ............... 5
Start-up ........................................... 5
g. Resetting the monitor ............... 6
E. Maintenance ....................................... ... 6
a. Replacing the cartridge ............ 6
F. Troubleshooting ........................................ 7
G. Parts List ....................................................... 7
H. Warranty ....................................................... 8
Tested and Certified by CSA Group to CSA Standard B483.1, to NSF/ANSI Standard 53 for
reduction of lead, VOC and Cyst (e.g. Cryptosporidium & Giardia), to NSF/ANSI Standard
42 for reduction of chlorine, taste & odour, and to NSF/ANSI 372 for low lead
requirements
The standards referenced above evaluate products for use with disinfected waters.
Thank you for purchasing a Rainfresh Product.
Most issues can be resolved over the phone.
Canada Toll Free :
Toronto and Area :
(Mon to Fri 8:30 AM to 5:00 PM EST)
1800 667 8072
(905) 884 9388
www.rainfresh.ca/QS1

Publicité

Table des Matières
loading

Sommaire des Matières pour Rainfresh Twist QS1

  • Page 1: Table Des Matières

    DRINKING WATER SYSTEM (MODELS QS1, QS1X) USER MANUAL Thank you for purchasing a Rainfresh Product. We are committed to ensuring that you are totally satisfied. If you have any problems, don’t go back to the store – please contact us ! Most issues can be resolved over the phone.
  • Page 2: Introduction

    (see “Maintenance” section for details). o This system is intended for use with cold water only. DO NOT INSTALL ON HOT WATER. o Only use Rainfresh TWIST filter cartridges with this unit. No other filter cartridge will fit or function with this system.
  • Page 3: Installation

    (such as basement or crawl space) from where tubing can be run to the faucet. The unit should not be installed more than fifteen feet away from the faucet. Call Rainfresh if you have questions.
  • Page 4: Mounting The Unit

    Step 2: Install battery (For model QS1 only) Before mounting the unit, install the monitor battery. Remove head cover insert (2713) by gently pulling away the insert from the head. Unwrap coin battery (2545) and insert into battery slot between contacts with + side out. Now re-attach the head cover 2713 insert (2713), carefully aligning it so that the black button on the monitor lines up through the hole on the cover insert.
  • Page 5: Start-Up

    Step 5: Installing the supply valve The self-piercing supply valve (1008-1) can be installed on copper or CPVC rigid plastic pipe of 3/8" to 1" diameter. NOTE: If your piping is PEX or any other softer material, DO NOT USE this supply valve as it can cause a water leak. For PEX, you can purchase appropriate fittings at the same store where you purchased this unit or you can order the supply valve kit (model CK514) online directly from www.rainfreshstore.com IMPORTANT: Before you install supply valve, confirm the cold water pipe by running...
  • Page 6: Maintenance

    6 month life is up. If your water has excessive sediment, we recommend installing a Rainfresh whole house water filter available from the same retailer where you purchased this unit. Call Rainfresh for assistance in locating a retailer and product selection.
  • Page 7: Troubleshooting

    Monitor does not light If water is not running through the system and the monitor LED does not light up when I press the up, you may need to replace the battery (2545). Call Rainfresh to order button (G) PARTS LIST...
  • Page 8: Warranty

    Envirogard/Rainfresh replacement cartridges have been used.
  • Page 9 MANUEL UTILISATEUR Nous vous remercions d'avoir acheté un de nos systèmes de désinfection ENVIROGARD/Rainfresh. Nous nous engageons à vous donner entière satisfaction. Si l'article vous cause un problème, ne retournez pas au magasin. Appelez-nous ! La plupart des problèmes peuvent être résolus par téléphone...
  • Page 10: Introduction

    NE PAS L’INSTALLER POUR L’EAU CHAUDE.   Utilisez uniquement des cartouches filtrantes Rainfresh TWIST avec ce dispositif. Aucune autre cartouche filtrante ne fonctionnera avec ce dispositif.  Ne pas lubrifier la tête des joints toriques avec des lubrifiants à base de pétrole. Le silicone alimentaire (composé...
  • Page 11: Unpacking The Unit

    à tout autre endroit distant à support mural (comme un sous-sol ou un vide sanitaire) d’où les tuyaux peuvent être acheminés jusqu’au robinet. L’appareil ne doit pas être installé à plus de 4,5 m (15 pi) du robinet. En cas de questions, appelez Rainfresh. Étape 1: Installation du robinet Le robinet peut être installé...
  • Page 12: Montage De L'unité

    Étape 2: Installation de la pile (modèle QS1 uniquement) Avant d’installer le système sous l’évier, installez la pile du témoin de remplacement. Pour ce faire, enlevez le couvercle (2713) de la tête, déballez la pile bouton (2545) et glissez-la entre les contacts, la borne positive vers l’extérieur.
  • Page 13: Installation De La Soupape À Étrier

    Étape 4: Installation de la soupape à étrier La soupape à étrier auto-perçante (1008-1) peut être installé sur un tuyau de plastique rigide en cuivre ou CPVC de 3/8 "à 1" de diamètre. REMARQUE: Si votre tuyau est en XLPE ou tout autre matériau plus souple, N’UTILISEZ PAS cette valve d’alimentation, car elle peut entraîner des fuites.
  • Page 14: Utilisation Et Entretien

    6 mois. Si votre eau contient trop de sédiments, nous vous recommandons d’installer un filtre à eau Rainfresh pour toute la maison disponible auprès du même détaillant que celui où vous avez acheté cet appareil. Appelez Rainfresh pour obtenir de l'aide pour localiser un détaillant et choisir un produit.
  • Page 15: Dépannage

    • Si le témoin ne s’allume pas pendant que l’eau ne coule pas, il se peut que la pas à la pression du pile soit morte. bouton. • Communiquez avec Rainfresh pour commander une pile de rechange (2545). (G) LISTE DES PIÈCES No pièce DESCRIPTION...
  • Page 16: Garantie

    été modifié ou qu’il a été utilisé incorrectement ou de façon abusive, et pourvu que seules de cartouche Rainfresh aient été utilisées. Cette garantie ne couvre pas le cartouche de rechange ni la pile du dispositif de contrôle. Le rendement de ces pièces diminue à la longue, et elles doivent être remplacées à...

Ce manuel est également adapté pour: