The operating indicator (3) flashes.
Conservation charge:
Once the charging process has finished, the battery charger automatically switches to conserva-
tion mode.
The battery pack can remain in the battery charger and is therefore always ready for use.
The operating display (3) lights up continuously.
Fault:
● Warning display (4) lights up continuously.
Battery pack is not charged. Temperature too high/ too low. When the temperature of the battery
pack is between 0 °C and 50 °C / 32° - 122° F, the charging process begins automatically.
● Warning display (4) flashes.
Battery pack is defective. Remove the battery pack immediately from the charger.
The battery pack was not pushed correctly onto the sliding seat (2).
6

Care and Maintenance

Charger:
Repairs to the charger must only be carried out by qualified electricians.
If the mains connection cable of this tool is damaged, in order to prevent endangering personnel
and property it must be replaced by the manufacturer, or the Customer Service of the manufac-
turer, or a similarly qualified person.
6.1

Routine maintenance

Periodic and correct maintenance of the vacuum pump will ensure a long operation life and con-
stant performance.
Lubrication
The oil provided with the pump has been specially formulated & manufactured to lubricate vacu-
um pumps; it is special as it features minimum viscosity fluctuation when in use under a wide
temperature range.
The type of lubricant supplied with the pump allows the evacuation of systems operating refrig-
erants. Only working with ROTHENBERGER POE synthetic oil.
The required amount of lubricating oil depends on the size of the pump container specified in the
section "Technical data" and must correspond to the quantity required until the dimensions of
the sight glass are reached.
Replace the oil charge no later than 20 hours of operation.
Oil could be polluted by other oil, humidity, refrigerants, etc. It is mandatory to use oil in perfect
conditions to assure a perfect performance of the pump.
Oil-change
Over-used lubrication oil damages the pumps' mechanism; make sure to replace oil as soon as
it starts to turn cloudy. For conducting the oil-change, the pump must be switched off. For
changing the oil proceed as follows:
 Unscrew the oil drainage plug located on the lower part of the pump
 Check that oil comes out completely from the pump
 Tightly screw the oil drainage plug back on
 Re-fill the pump with oil (see "Filling of oil")