Spécifications D'installation - RJG Lynx LS-MD-040 Manuel Du Produit

Table des Matières

Publicité

Drawing Title: LS-MD-040-03
SPÉCIFICATIONS D'INSTALLATION
Parting Line
B
NOTES:
1.
ENCLOSED EJECTOR BOX SUGGESTED.
2.
DO NOT SCALE PRINT
3.
BREAK ALL SHARP EDGES, 0.005 [0.03] R MAX
4.
DIMENSIONS IN INCHES [MM], UNLESS NOTED
5.
TOLERANCES UNLESS SPECIFIED:
XXX = 0.003 [0.08]
XX = 0.01 [0.3]
ANGLES = 3 30
6
RJG, Inc.
Lynx™ Mold Deflection Sensor LS-MD-040 Installation
Ejector Pin 5/16"
with .5 x .25 head
[DIN 6 mm, 12 x 5]
.040
1.016
Hole Depth (H1)=
Mold Height - Mold Depth - Cover Plate Depth
.475
12.07
when compressed
.10
2.54
.25 MIN
6 MIN
Pin Length (H2) =
H1 + Pin Head Height + 0.040 [1.016]
D
C
0.001 [0.03] D
0.001 [0.03]
0.001 [0.03] C
0.001 [0.03]
with 5/16" pin
[6.03 with 12 mm pin]
.040
X 45° Chamfer
1
.375
9.53
.510 +
.005
-
.000
+ 0.13
12.95
0
DETAIL B
SCALE 3 : 1
Lynx™ Capteurs de Déflexion Moule LS‑MD‑040 | Manuel du Produit
.314
+
.003
1.190
-
.000
with .5 x .25
pin head
29.14 +.08
-.00
WITH 12 X 5 mm
PIN HEAD
Description: LS-MD-040
Sensor Installation
Drawn: K.J.Brettschneider
Design:
Check: M.Groleau
Date: 02.04.2022

Publicité

Table des Matières
loading

Table des Matières