Télécharger Imprimer la page

Troubleshooting Chart - Symmons Maxline 4698035 Mode D'emploi

Publicité

Les langues disponibles

Les langues disponibles

Care and Cleaning
Remove cartridge and clean valve body in household vinegar to remove corrosive mineral build up. Rinse
under running hot water to ensure valve is free of foreign debris.

Troubleshooting Chart

Problem
Water flow is less than normal.
Valve is leaking around the cap
retaining nut area.
Tempered hot water temperature
is not hot enough.
Symmons Industries, Inc.
©2015 Symmons Industries, Inc.
Screen in valve is dirty or cartridge
is dirty or clogged.
Water leaking from o-ring seal.
Hot water supply into valve is not
10°F (5.55°C) above desired set
point temperature.
31 Brooks Drive
Braintree, MA 02184
www.symmons.com
Cause
Phone: (800) 796-6667
gethelp@symmons.com
Solution
1) Remove filter washer and clean
under running water or replace by
ordering check valve/union fitting
replacement kit.
2) Remove cartridge and clean in
household vinegar or replace by
ordering cartridge replacement kit.
Replace o-ring by ordering
cartridge replacement kit.
Increase hot water supply
temperature into valve.
Fax: (800) 961-9621
ZV-3009 REV E
012815

Publicité

loading