Symmons Maxline 4698035 Mode D'emploi

Publicité

Les langues disponibles

Les langues disponibles

Operation & Maintenance
Initial 30 Day Inspection
Inspect cartridge within 30 days of initial operation.
If inspection determines that your water system is
causing deposits and foreign matter to build-up,
then adjust cartridge maintenance accordingly.
Cartridge Replacement
1) Shut off hot and cold water supplies to valve.
2) Remove safety cap by inserting a small
screwdriver into the widest opening at the base
of the cap and pry upward. This will expose the
cartridge stem and cartridge retaining unit.
3) Remove retaining nut by turning counter-clockwise
with adjustable wrench. Grasp cartridge with
pliers and remove from body by pulling straight
out. A slight rocking rotation may be required to
loosen while removing.
4) Lubricate cartridge o-rings with a small amount of
lubricant prior to reinstalling. Insert replacement
cartridge into valve body, applying enough force to
ensure cartridge is fully seated. Install cartridge
with keyway inline with Symmons logo located
retaining nut
Torque to 132 inch lbs. (15Nm)
on front of valve casting as shown below to the
left. Install retaining nut back onto valve body.
5) Refer to "Setting Valve Temperature" section (pg.4)
to properly set valve to desired temperature.
Service Instructions
Cleaning or replacing filter washer and check valve:
1) Remove union adapter nut from valve body and
then valve fitting from union adapter.
2) Clean filter washer seated in valve fitting by
soaking both in household vinegar and rinse under
running water. Ensure not to damage screen in
filter washer.
3) Replace filter washer into center of valve fitting.
4) Replace check valve by removing from center of
valve body port connection.
5) Fasten and tighten union adapter nut over valve
fitting to valve body.
Seasonal Use
If valve is used seasonally, such as in schools or
campgrounds, then perform the following steps to
avoid damage caused by freezing water when valves
are not in use:
1) Shut off hot and cold water supplies.
2) Remove valve cartridge and drain all water.
3) Drain water from the supply lines and valve body.
6

Publicité

Table des Matières
loading

Sommaire des Matières pour Symmons Maxline 4698035

  • Page 1 Install cartridge Seasonal Use with keyway inline with Symmons logo located If valve is used seasonally, such as in schools or retaining nut campgrounds, then perform the following steps to Torque to 132 inch lbs.
  • Page 2: Troubleshooting Chart

    ■ ■ ■ ■ Symmons Industries, Inc. 31 Brooks Drive Braintree, MA 02184 Phone: (800) 796-6667 Fax: (800) 961-9621 ■ ■ ■ ■ ©2015 Symmons Industries, Inc. www.symmons.com gethelp@symmons.com ZV-3009 REV E 012815...
  • Page 3: Reemplazo Del Cartucho

    Funcionamiento y mantenimiento Inspección dentro los 30 días del inicio cartucho con el chavetero en línea con el logotipo de Symmons situado en la parte delantera de la del funcionamiento fundición de la válvula como se muestra abajo a la izquierda.
  • Page 4: Tabla De Solución De Problemas

    ■ ■ ■ ■ Symmons Industries, Inc. 31 Brooks Drive Braintree, MA 02184 Phone: (800) 796-6667 Fax: (800) 961-9621 ■ ■ ■ ■ ©2015 Symmons Industries, Inc. www.symmons.com gethelp@symmons.com ZV-3009 REV E 012815...
  • Page 5: Remplacement De La Cartouche

    Insérez la cartouche avec une rainure en ligne avec le étapes suivantes pour éviter les dommages logo Symmons situé sur l’avant du boîtier de la vanne, causées par l’eau surgelée lorsque les vannes comme montré plus bas à la gauche. Réinstallez ne sont pas utilisées.
  • Page 6 à la température désirée. ■ ■ ■ ■ Symmons Industries, Inc. 31 Brooks Drive Braintree, MA 02184 Phone: (800) 796-6667 Fax: (800) 961-9621 ■ ■ ■ ■ ©2015 Symmons Industries, Inc. www.symmons.com gethelp@symmons.com ZV-3009 REV E 012815...

Table des Matières