Alarm-relay activation time:
D
P I
7
O
F
F
O
N
Number of areas:
D
P I
8
O
F
F
O
N
PROGRAMMING, SECOND LEVEL (THROUGH JUMPERS S1 AND S2):
The functions programmable through jumpers S1 and S2 are the following:
E
•
Acquisition and cancellation of proximity keys
N
•
Association of the zones to arming and/or areas
•
Zone adjusting Switch Alarm
G
INPUT IN PROGRAMMING, SECOND LEVEL:
1.
Ensure that both areas are disarmed
2.
Press and keep pressed pushbutton PB on front of control panel
3.
A.
First access: insert any proximity key into the RD reader on control panel
B.
Following accesses: insert one MASTER key into the RD reader on control panel
4.
When the battery Led starts blinking, remove the key from the reader RD keeping the button
PB pressed.
The MASTER key is a key acquired by the RD reader on control panel
5.
If the procedure is accepted, there will be a short contemporary flashing of all zone leds and in
case of first access the key is memorized as MASTER
6.
Remove the key from RD reader and release PB pushbutton
7
A 40 seconds time lapse is activated, during which the battery led blinks quickly and the zone leds
flash alternatively. During this time-lapse and during the whole programming permanence, the control
panel Tamper and zone 1 if programmed as 24 hours, will be excluded.
8.
Open control panel housing
9.
Place jumpers S1 and S2 according to the programming to make.
Programming remains active until jumper S1 remains inserted in any position and for further
40 seconds since when it is opened. During the whole programming time the battery led
blinks quickly.
LEAVING PROGRAMMING, SECOND LEVEL
1.
At the end of programming, re-open jumper S1
2.
A time lapse of 40 seconds is activated, during which the Battery led continues blinking . close
control panel box and wait to leave from programming, shown by switching off of Battery led . At the
end of battery led blinking, the control panel tamper and zone 1 if programmed as 24 hours, are re-
activated.
Acquisition of proximity keys (max 8 for Lucky 4 and max 16 for Lucky 8):
During this procedure, all RS readers connected to RS485 serial are acquired.
1.
Close jumper S1 in position 4 on control panel board
2.
Approach the key to acquire to a reader associated to the operating area.
• RS Readers:
l A
r a
m
i t
m
e
6
0
s
e
c
o
n
d
s
1
8
0
s
e
c
o
n
d
s
N
u
m
b
e
s r
f o
a
e r
a
s
1
a
e r
a
2
a
e r
a
s
Led 2 Red it blinks slowly if the key is correctly acquired
Led 2 Red blinks quickly if the key has already been memorized
Led 1 and Led 3 Red the blink quickly if the key-memory is full
The time of activation of the free exchange C – NC – NO of
alarm relay and of outputs +SA and +S can be set with following
values
It is possible to manage a single area in three different
arming modes. (ON, HOME and AREA) or two areas, in this
latter case arming modes can be two for main area (ON
and HOME) and 1 for the secondary area (ON)
- 28 -