Electrical Connection; Extension Lead; Warranty; Important Warnings - MIRKA Dust Exrtactor 1230 Instructions D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

en
READ AND FOLLOW ALL SAFETY INSTRUCTIONS .
Any other use is considered as improper use . The manufacturer accepts no liability for any damage resulting from such
use . The risk for such use is borne solely by the user . Proper use also includes proper operation, servicing and repairs as
specified by the manufacturer .
For Dust Class L machines the following applies:
The appliance is suitable for picking up dry, non-flammable dust and liquids, hazardous dust with OEL (Occupational
Exposure Limit) values > 1 mg/m
Dust Class L (IEC 60335-2-69) . Dust in this class has OEL values > 1 mg/m
filter material has been tested . The maximum degree of permeability is 1% and there is no special requirement for
disposal .
For dust extractors, ensure adequate air change rate L, when the exhaust air is returned to the room . Observe national
regulations before use .

1.4 Electrical connection

• It is recommended that the machine should be connected via a residual current circuit breaker .
• Arrange the electrical parts (sockets, plugs and couplings) and lay down the extension lead so that the protection
class is maintained .
• Connectors and couplings of power supply cords and extension leads must be watertight .

1.5 Extension lead

1 . Only use the version of extension lead specified by the manufacturer, or one of a higher quality .
2 . When using an extension lead, check the minimum cross-sections of the cable:
Cable length
≤ 20 m
20–50 m

1.6 Warranty

Our general conditions of business are applicable with regard to the warranty . Unauthorised modifications to the
appliance, the use of incorrect brushes and use of the appliance in a way other than for the intended purpose exempt
the manufacturer from any liability for the resulting damage .

1.7 Important warnings

WARNING
• To reduce the risk of fire, electric shock, or injury, please
read and follow all safety instructions and caution markings
before use. This machine is designed to be safe when used
for cleaning functions as specified. Should damage occur to
electrical or mechanical parts, the machine and/or accessory
12
Mirka® Dust Extractor • 1230 L • PC & AFC • 110–120 V
.
3
Cross section < 16 A
1,5 mm
2
2,5 mm
2
3
. For machines intended for Dust Class L, the
Cross section < 25 A
2,5 mm
2
4,0 mm
2

Publicité