Troubleshooting
Occasionally, a problem is minor and a service call may not be necessary- use this troubleshooting guide for a possi-
ble solution. If the unit continues to operate improperly, call an authorized service depot or Danby's Toll Free Number
1-844-455-6097 for assistance.
PROBLEM
The party center does not
operate
The party center is not
cold enough
Turns on and off frequently •
The light does not work
Vibrations
The party center seems to
make too much noise
POSSIBLE CAUSE
•
Not plugged in
•
The appliance is turned off
•
No power to unit
•
Check the temperature control
setting
•
External environment may require
a cooling setting
•
The door is opened too often
•
The door is not closed completely
•
The door gasket does not seal
The room temperature is hotter
than normal
•
A large amount of beverage has
been added to the party center
•
The door is opened too often
•
The door is not closed completely
•
The temperature control is not set
correctly
•
The door gasket does not seal
properly
•
Not plugged in
•
No power
•
The light button is "OFF"
•
Ensure that the party center is
level
•
The rattling noise may come from
the fl ow of the refrigerant, which is
normal. As each cycle ends, you
may hear gurgling sounds caused
by the fl ow of refrigerant in your
party center.
•
Contraction and expansion of the
inside walls may cause popping
and crackling noises.
•
The party center is not level
10
SOLUTIONS
•
Plug in the unit
•
Press the ON button
•
Reset circuit breaker; check fuses
•
Adjust setting as needed
•
Adjust setting as needed
•
Limit open door duration
•
Close door securely
•
Ensure the gasket is clean
•
This is normal
•
Limit amount of warm beverage
introduced at one time
•
Limit amount of door openings
•
Close door securely
•
Adjust setting as needed
•
Ensure the gasket is clean
•
Plug in the unit
•
Reset circuit breaker; check fuses
•
Switch light button to "ON"
•
Level the party center, see "Instal-
lation Instructions"
•
This is normal
•
This is normal
•
Level the party center