MOUNTING AND WIRING INSTRUCTIONS
NOTE: Underwriters Laboratories (UL) does not require all fixtures to have ground wires. These fixtures meet all UL
specifications.
CAUTION: For fixtures labeled for outdoor and wet location use, provide a water-tight seal between the fixture and
the mounting surface by using silicone or similar caulking.
1. Turn off power at circuit box to avoid possible electric shock.
2. Thread mounting screws (A) into mounting bar (B) approximately 5/8 inch (see fig. 1).
3. Secure mounting bar (B) to outlet box (C) with outlet box screws (D) (not included).
4. Identify color coding of fixture wires (see figure 2 on page 11).
5. To connect wires, take black fixture wire (group A from fig. 2) and place evenly against black outlet box wire.
Do not twist wires.
6. Fit wire connector (F from fig. 1) over wires and twist until there is a firm connection. If wire connector (F)
easily comes off, reattach and check again for a firm connection (see figure 1).
7. Repeat steps 5 and 6 with the white (group B from fig. 2) fixture and outlet box wires.
8. Partially thread green grounding screw (G) into side hole (H) on mounting bar (B) (see fig. 1).
9. Wrap ground wire from fixture and ground wire (metal or green wire) from outlet box (C) around green
grounding screw (G) on mounting bar (B).
10. Tighten green grounding screw (G). Do not over tighten.
11. Tuck wires inside outlet box (C).
FIXTURE ASSEMBLY INSTRUCTIONS
1. To remove fixture cover, remove cap nuts (L). Be sure to carefully take off the glass shade (K) while removing
the fixture cover
2. Raise canopy (I) to ceiling allowing mounting screws (A) to protrude through key slots (N) in canopy (J)
(see fig. 1).
3. Rotate canopy (I) clockwise until mounting screws (A) lock into narrow portion of key slots (J).
4. Install lamp(s). Do not exceed recommended wattage.
5. Secure glass shade (K) onto canopy (I) with fixture cover (E) and cap nuts (L).
6. Turn power back on at circuit box.