LEGEND OF SYMBOLS
Parts to read carefully.
Parts regarding safety.
LS:
limit switch.
The moving element: means any boxed awnings, awnings,
shutters, blinds, unless otherwise specifi ed.
The number of click-clacks at the end of the
sequence corresponds to the tilt movements
done by the motor to visually signal that
the procedure has been undertaken by
the receiver.
Maximum time to perform the procedure
once operator is powered up.
1'

BEFORE INSTALLING

- Do not allow children to play with the Transmitter.
- Make sure to stay clear of the moving element until it has
completely stopped.
- Frequently check the system for any signs of
unbalancing, of wear and tear or damage.
- To clean the moving element, cut off the power supply
to the motor.

INTENDED USE

Receving control-unit for motors with mono-phase,
asynchronous, electro-mechanical limit-switches, which
is powered by electrical current and designed to operate
awnings, shutters and similar systems.
Versions
Compatible with all the transmitters from the KLT series that
work at the same frequency.
Any installation and use other than that specifi ed in
this manual is forbidden.

Technical data

KLT-50
Protection rating
IP55
Maximum power of motors
500 w / 400 VA
Working temperature
-10°C / +55°C
Power supply
230 V AC ± 5% 50 Hz
Receiving frequency
433,92 MHz / 868.35 MHz
Duration of manoeuvre
4 min.
Dimensions / weight
100 X 27 X 21 / 45 g
KLT-120
Protection rating
IP55
Maximum power of motors
800 w / 650
Working temperature
-10°C / +55°C
Power supply
230 V AC ± 5% 50 Hz
Receiving frequency
433,92 MHz / 868.35 MHz
Duration of manoeuvre
4 min.
Dimensions / weight
113 X 35 X 20 / 60 g
Cable type and section
Connection for
Power supply panel
Cable type
EN 50267-2-1
Cable length 1 < 10 m
3G x 0.75 mm
Cable length 10 < 20 m
3G x 1 mm
Cable length 20 < 30 m
3G x 1.5 mm
Connection for
Power supply to motor
FR0R CEI 20-22 CEI
Cable type
EN 50267-2-1
Cable length 1 < 10 m
4G x 0.75 mm
Cable length 10 < 20 m
4G x 1 mm
Cable length 20 < 30 m
4G x 1.5 mm
INSTALLATION
Installation must be done by skilled, qualified
technicians in accordance with current regulations.
All connections must be made when the electrical
power is cut off .
- Strip the motor power-supply cable by about 3 cm and
itzs single wire by about 5 mm.
- Open the container by removing the cable-gland cap (see
Fig.
).
- Extract the control board by a few centimetres from the
container (see Fig.
- Thread the two cables in the corresponding cable-gland
holes in the cap (see Fig.
- Connect the wires to the terminals
the diagram in Fig.
"Electrical connections" chapter).
- Fold the cables back (see Fig.
- Push the control board into the container and run the cap
along the cables until it closes (see Fig.
Do not perforate the container for any reason .
Check that the Stripped part of the cable is entirely
inside the container.
Preliminary checks
The control unit can be fastened to the inside of the awning
2
box or inside a junction box, provided it is protected from
2
any impacts. Install on solid, fl at surfaces, and use two-way
2
adhesive tape if necessary. To off set the risk of water leaks,
the control unit must be replaced with the cables pointing
downwards (see Fig.
facing upwards (see Fig.
Set up proper conduits and electric cable raceways,
2
making sure these are protected from any mechanical
2
damage.
2
).
).
, while respecting
and what is established in the
).
).
). Do not replace it with the cables
).
119T70531