Page 1
9 1 1 3 9 1 1 3 C o n v e r t i s s e u r p r o g r a m m a b l e [ E x i a ] N o . 9 1 1 3 V 1 0 3 - F R P r o d u c t v e r s i o n : 9 1 1 3 - 0 0 3 S I G N A L S T H E B E S T S I G N A L S T H E B E S T...
Page 2
PR electronics A/S tilbyder et bredt program af analoge og digitale signalbehandlingsmoduler til industriel automation. Programmet består af Isolatorer, Displays, Ex-barrierer, Temperaturtransmittere, Universaltransmittere mfl. Vi har modulerne, du kan stole på i selv barske miljøer med elektrisk støj, vibrationer og temperaturud- sving, og alle produkter opfylder de strengeste internationale stan- darder.
électrostatiques (ESD) : montage général, raccordement et débranchement de fils et recherche de pannes sur le module. Seule PR electronics SARL est autorisée à réparer le module et à remplacer les fusibles. AVERTISSEMENT Ne pas ouvrir la plaque avant du module au risque d’endommager...
: peut couper la tension du module. Pour une installation sur le rail d’alimentation 9400, le module sera alimenté par le contrôleur d’alimentation 9410. L’année de production est définie par les deux premiers chiffres du numéro de série. 9113 - Product Version 9113-003...
Dans la mesure où les instructions de ce guide ne sont pas strictement respectées par le client, ce dernier n’est pas en droit de faire une réclamation auprès de PR electronics SARL, même si cette dernière figure dans l’accord de vente conclu.
: EN 60079-0 : 2009 Organisme notifié KEMA Quality B.V. (0344) Utrechtseweg 310, 6812 AR Arnhem P.O. Box 5185, 6802 Ed Arnhem The Netherlands Rønde, le 27 juin 2012 Kim Rasmussen Signature du fabricant 9113 - Product Version 9113-003...
• Recopie de la configuration d’un module à d’autres du même type à l’aide de la façade de programmation. • Les entrées TC peuvent utiliser soit la CSF interne soit le bornier avec capteur Pt100 incorporé (PR 5910Ex, voie 1 / PR 5913Ex, voie 2) pour une précision améliorée. • Le 9113 détecte automatiquement s’il doit fournir un signal de courant actif ou passif. • Contrôle avancé de la communication interne et les données sauvegardées.
SIL (ouvert / verrouillé). Point statique = verrouillage SIL, point clignotante = aucun vérrouillage SIL. • L’accès à la programmation peut être bloqué par un mot de passe. Ce mot de passe est sauvegardé dans le module afin d’assurer un haut niveau de protection contre les modifications non autorisées. Montage / installation • Cliquer le 4501 sur la face avant du 9113 9113 - Product Version 9113-003...
Temps de réponse moyen, délai inclu : ≤ Entrée température ......≤ Entrée mA ..........0,4 s Température d’étalonnage ......20...28°C Précision, la plus grande des valeurs générales et de base : Valeurs générales Type Précision Coefficient de d’entrée absolue température...
Page 12
Poids ............250 g / 265 g avec 4501 Isolation : Entrée aux autres ........300 Vca double / renforcée Sortie analogique à l’alimentation ....300 Vca double/renforcée Relais d’état à l’alimentation ....... 150 Vca double/renforcée ou 300 Vca isolation de base 9113 - Product Version 9113-003...
Page 13
Compensation de soudure froide (CSF) : avec capteur incorporé dans le bornier 5910 ........20...28°C ≤ ±1°C -20...20°C et 28...70°C ≤ ±2°C avec capteur CSF interne ....±(2,0°C + 0,4°C * ∆t) ∆t = température interne - température ambiante 9113 - Product Version 9113-003...
Page 14
Approbation marine : Det Norske Veritas, Ships & Offshore ..Stand. f. Certific. No. 2.4 Approbation GOST R : VNIIFTRI, Cert No........Voir www.prelectronics.fr Certifcation SIL : exida, Cert No..........PREl 070902 P0002 C03.01 9113 - Product Version 9113-003...
Page 15
IEC 61241-0 et -11 c FM us ............FM 3600, 3611, 3810 CSA E60079-0, -15 CSA 22.2 -25, -142, -213 ANSI/ISA-12.00.01 / 12.12.02 UL, Standard for Safety ......UL 61010-1 SIL .............IEC 61508 EC = Echelle configurée 9113 - Product Version 9113-003...
Voir conditions ci-dessus Défaut capteur CSF interne ou temp. Vérification du capteur CSF interne CJ.ER CSF dépasse l’échelle** Bornier CSF en défaut ou manquant, Erreur connecteur CSF - contrôler le bornier CSF CJ.CE température dépasse l’échelle valable 9113 - Product Version 9113-003...
Page 17
** L’erreur est corrigée soit en parcourant les menus, soit en déconnectant et puis reconnectant l’alimentation du module. L’erreur peut être négligée en sélectant un type d’entrée autre que TC. *** L’erreur est corrigée en parcourant les menus. 9113 - Product Version 9113-003...
OPERATION dES TOUChES dE fONCTION Documentation pour le diagramme de programmation. Généralités Lors de la configuration du 9113 vous êtes guidés tout au long des paramètres du menu ; ainsi vous pouvez choisir le réglage qui correspond à votre application. Pour chaque menu il y a un texte d’aide qui défile en ligne 3 de l’indicateur.
CSf (CJC) Dans le menu CJC vous pouvez choisir entre connecteur CSF ou compensation de soudure froide interne. Le connecteur CSF (PR 5910Ex/5913Ex) est à commander séparemment. Informations relatives à l’erreur de câble sur la façade 4501 Erreur de câble (voir limites dans tableau) est affichée par CA.BR (rupture câble) ou CA.SH (court circuit câble).
Page 23
Rail d’alimentation : Dans le menu ”RAIL” vous pouvez choirsir si des erreurs capteur doivent être transmis à l’unité de surveillance du module PR 9410 Contrôleur d’alimentation. Safety Integrity Level: Voir le ”Safety Manual” (en Anglais) pour informations complémentaires.
1 Incrémenter la valeur / choisir paramètre suivant 2 Décrémenter la valeur / choisir paramètre précédent 3 Valider les valeurs choisies et fin du menu Maintien 3 Retour au menu précédent / retour au menu 1.0 sans sauvegarde 12 mA 12 mA 100C 100C Si le vérrouillage SIL est activé...
Page 25
-199.9 Configuration 150.0 150.0 de la voie 2 Retour au menu 1.0 identique OUT.LO OUT.LO OUT.HI OUT.HI RESP. RESP. Txt 14 Txt 14 Txt 15 Txt 15 Txt 35 Txt 35 à la voie 1 9113 - Product Version 9113-003...
[50] Erreur CSF - contrôler le bornier CSF [14] Régler température de la sortie analogique basse [51] Pas de communication [15] Régler température de la sortie analogique haute [16] Activer signal d’état du rail d’alimentation 9113 - Product Version 9113-003...
APPENdIX IECEx Installation drawing ATEX Installation drawing fM Installation drawing Safety manual 9113 - Product Version 9113-003...
Page 29
For Installation in Zone 2 / Division 2 the following must be observed. The 4501 programming module is to be used solely with PR electronics modules. It is important that the module is undamaged and has not been altered or modified in any way. Only 4501 modules free of dust and moisture shall be installed.
Page 30
Do not separate connectors when energized and an explosive gas mixture is present. Do not mount or remove modules from the Power Rail when an explosive gas mixture is present. Revision date: Version Revision: Prepared by: Page: 2009-11-27 V3 R0 9113 - Product Version 9113-003...
Pour l'installation dans la zone 2 / Division 2 on doit observer ce qui suit. Le module de programmation 4501 doit être employé seulement avec des modules de PR electronics. Il est important que le module soit intact et n'ait pas été changé ou n'ait pas été...
Page 33
« la sécurité intrinsèque », le module ne peut pas être réinstallé dans le type de protection « sécurité intrinsèque ». Ne déconnecter pas les connecteurs une fois activé et dans un environnement en présence de gaz. Ne montez pas ou n'enlevez pas les modules du rail d’alimentation est présence d’un mélange de gaz.
For Installation in Zone 2 / Division 2 the following must be observed. The 4501 programming module is to be used solely with PR electronics modules. It is important that the module is undamaged and has not been altered or modified in any way.
Page 36
Warning: Do not mount or remove modules from the Power Rail when an explosive gas mixture is present. Revision date: Version Revision: Prepared by: Page: 2009-11-27 V3 R0 9113 - Product Version 9113-003...
Page 37
Group A,B Group C,E,F Group D,G 0.3 F 1.6 F 8 F 80 mH 250 mH 600 mH 10 V 30 mA 15 nF 1.7 μH Revision date: Version Revision: Prepared by: Page: 2009-11-27 V3 R0 9113 - Product Version 9113-003...
9113 TeMpeRaTuRe / ma CONVeRTeR Safety Manual Observed standards Standard Description Functional Safety of electrical / electronic / programmable electronic IeC 61508 safety-related systems IeC 61508- part 2: Requirements for electrical / electronic / programmable electronic 2:2000 safety-related systems IeC 61508- part 3: Software requirements 3:1998 IeC 61326-3- Immunity requirements for safety-related systems 1:2008 acronyms and abbreviations acronym / Designation Description abbreviation Term defined by IeC 61508 as “part of a subsystem comprising a single component or any element group of components that performs one or more element safety functions” This is the likelihood of dangerous safety function probability of Failure pFD failures occurring on demand. on Demand The term “probability” is misleading, as IeC probability of danger- 61508 defines a Rate. ous Failure per Hour...
Safety Manual 9113 TeMpeRaTuRe / ma CONVeRTeR assumptions and restrictions for use of the product Basic safety specifications Operational temperature range.... -20...+60°C Storage temperature range...... -20...+85°C power supply type, min...... Double or reinforced Supply voltage ......... 19.2...31.2 VDC external loop supply voltage .... 5...26 VDC + external drop Mounting area .......... Zone 2 / Division 2 or safe area Mounting environment ...... pollution degree 2 or better Safety accuracy The analogue output corresponds to the applied input within the safety accuracy. Safety accuracy ........ ±2% 4.2.1 minimum span For temperature measurements, the selected range (OuT.HI - OuT.LO)
SIL-mode is entered, in addition to the normal functional test. Refer to section 14 - Safe parameterisation - user responsibility. 4.3.4 analogue output The connected safety pLC shall be able to detect and handle the fault indications on the analogue output of the 9113 converter by having a NaMuR Ne43-compliant current input. failure rates The basic failure rates from the Siemens standard SN 29500 are used as the failure rate database.
Safety Manual 9113 TeMpeRaTuRe / ma CONVeRTeR Safety parameters probability of dangerous Failure per Hour (pFH) 6.10e-08 Note probability of failure on demand (pFD) - 3.96e-04 1 year proof test interval proof test interval (10% of loop pFD) 3 years Safe Failure Fraction 90.7 % Demand response time Signal input: < 0.5 seconds Temperature input: < 1.1 seconds Demand mode High Demand rate 3000 seconds Mean Time To Repair (MTTR) 24 hours Diagnostic test interval 30 seconds Hardware Fault Tolerance (HFT) Component Type SIL capability SIL 2 Description of the “Safe State” Output ≤ 3.6 ma or output ≥ 21 ma Note1: The 9113 contains no lifetime limiting components, therefore the pFH figures are valid for up to 12 years, according to IeC 61508. Hardware and software configuration all configurations of software and hardware versions are fixed from factory, and cannot be changed by end-user or reseller.
Repair of the device and replacement of circuit breakers must be done by pR electronics a/S only. 12 maintenance No maintenance required. 13 Documentation for routing diagram The routing diagram is shown in section 16.2. 13.1 In general When configuring the 9113, you will be guided through all parameters and you can choose the settings which fit the application. For each menu there is a scrolling help text which is automatically shown in line 3 on the display. Configuration is carried out by use of the 3 function keys: 1 will increase the numerical value or choose the next parameter 2 will decrease the numerical value or choose the previous parameter 3 will accept the chosen value and proceed to the next menu When configuration is completed, the display will return to the default state 1.0. pressing and holding 3 will return to the previous menu or return to the default state (1.0) without saving the changed values or parameters.
Safety Manual 9113 TeMpeRaTuRe / ma CONVeRTeR 13.2 further explanations 13.2.1 password protection access to the configuration can be blocked by assigning a password. The password is saved in the device in order to ensure a high degree of protection against unauthorised modifications to the configuration. Default password 2008 allows access to all configuration menus. password protection is mandatory in SIL applications. 13.2.2 Sensor/cable fault information via display front 4501 When the function is enabled and supported by selected input type, sensor or cable faults are displayed as Se.BR (sensor break) or Se.SH...
9113 TeMpeRaTuRe / ma CONVeRTeR Safety Manual 13.3.5 process calibration (Cal) a process calibration can be made by the end user. a known process signal must be applied for both low and high end of the input measurement range. The known input of the applied low end signal must be entered in the CaL.LO menu and confirmed by pressing OK before removing or changing the applied signal to the high end signal. The known input of...
Safety Manual 9113 TeMpeRaTuRe / ma CONVeRTeR 14 Safe parameterisation - user responsibility 14.1 Safety-related configuration parameters 14.1.1 parameters related only to Channel 1 Name Function CH1.TYp Selected input type: TeMp = Temperature CuRR = Current I.RaNGe Selected fixed input range for current measurements (for CH1. TYp = CuRR): 0_20 = 0...20 ma (no sensor error detection!) 4_20 = 4...20 ma CONNeC Selected sensor connection type for RTD measurements (for SeNSOR = Ni or pt):...
Page 49
9113 TeMpeRaTuRe / ma CONVeRTeR Safety Manual Name Function Ni.TYpe Ni sensor type (for SeNSOR = Ni): 50 = Ni50 100 = Ni100 120 = Ni120 1000 = Ni1000 TC.TYpe Thermocouple type (for SeNSOR = TC): TC.B = Thermocuple type B TC.e = Thermocuple type e TC.J = Thermocuple type J TC.K = Thermocuple type K TC.L = Thermocuple type L TC.N = Thermocuple type N TC.R = Thermocuple type R TC.S = Thermocuple type S TC.T = Thermocuple type T TC.u = Thermocuple type u TC.W3 = Thermocuple type W3 TC.W5 = Thermocuple type W5 TC.Lr = Thermocuple type Lr CJC type for SeNSOR = TC: INT = Internal CJC sensor measurement CONN = CJC connector measurement (accessory) O.RaNGe Fixed output range for current output: 0-20 = 0...20 ma Not valid when eN.SIL = YeS (Safety applications) 4-20 = 4...20 ma 20-0 = 20...0 ma Not valid when eN.SIL = YeS (Safety applications) 20-4 = 20...4 ma Version No. V5R0...
Page 50
Safety Manual 9113 TeMpeRaTuRe / ma CONVeRTeR Name Function OuT.eRR Fixed output value on detected sensor error: NONe = Sensor error detection NOT enabled, output at sensor error is undefined. The end user must ensure that the applied sensor including wiring has a failure rate qualifying it for the safety application without the detection enabled. 0 ma = Output is 0 ma at sensor error 3.5 ma = Output is 3.5 ma at sensor error (Ne43 downscale) 23 ma = Output is 23 ma at sensor error (Ne4 upscale) OuT.LO Selected temperature value for 0% output for CH1.TYp = TeMp in units defined by the uNIT parameter (°C or °F) Range is defined by the selected temperature sensor (SeNSOR and TC.TYpe, Ni.TYpe or pt.TYpe), but value must be less than OuT.HI - minimum span. OuT.HI Selected temperature value for 100% output for CH1.TYp =...
9113 TeMpeRaTuRe / ma CONVeRTeR Safety Manual 14.1.2 parameters related only to Channel 2 (only for type 9113BB) Name Function CH1.TYp Functions as described for Channel 1 (14.1.1) I.RaNGe CONNeC uNIT SeNSOR pt.TYpe Ni.TYpe TC.TYpe O.RaNGe OuT.eRR OuT.LO OuT.HI ReSp uSe.CaL 14.1.3. parameters related to both channels Name Function NeW.paS password for protection of the device configuration from un-authorized access. Range from 0 to 9999.
Safety Manual 9113 TeMpeRaTuRe / ma CONVeRTeR 14.2.1 If no password is set action Display shows press OK aDV.SeT Set (aDV.SeT) to Yes and press OK SeTup Set SeTup to SIL and press OK eN.SIL Set eN.SIL to YeS and press OK NeW.paS Set password to a number between 0 and CONFIG 9999 and press OK Verify (at this time the device starts operating OpeN->LOCK* in SIL mode with the entered configuration parameters!) press OK to confirm verification of the OpeN- CH1.TYp >LOCK in the display Verify input type for Channel 1 and press OK I.RaNGe Verify fixed input range and press OK CONNeC (ONLY IF CH1.TYp = CuRR) Verify sensor connection type and press OK uNIT (ONLY IF SeNSOR = Ni or pt and CH1.TYp = TeMp) Verify temperature unit and press OK SeNSOR (ONLY IF CH1.TYp = TeMp)
Page 53
9113 TeMpeRaTuRe / ma CONVeRTeR Safety Manual action Display shows Verify CJC type and press OK O.RaNGe (ONLY IF SeNSOR = TC and CH1.TYp = TeMp) Verify fixed output range and press OK OuT.eRR Verify fixed output value on detected sensor error OuT.LO and press OK (ONLY IF CH1.TYp = TeMp, or IF I.RaNGe = 4-20 Verify temperature for 0% output and press OK OuT.HI (ONLY IF CH1.TYp = TeMp) Verify temperature for 100% output and press OK ReSp (ONLY IF CH1.TYp = TeMp) Verify analogue output response time and press OK CH2.TYp Verify input type for Channel 2 and press OK I.RaNGe Verify fixed input range and press OK CONNeC (ONLY IF CH2.TYp = CuRR) Verify sensor connection type and press OK uNIT (ONLY IF SeNSOR = Ni or pt and CH2.TYp = TeMp) Verify temperature unit and press OK SeNSOR (ONLY IF CH2.TYp = TeMp) Verify temperature sensor type and press OK pt.TYpe ( ONLY IF CH2.TYp = TeMp) Verify pt sensor type and press OK Ni.TYpe (ONLY IF SeNSOR = pt and CH2.TYp = TeMp) Version No. V5R0...
Page 54
Safety Manual 9113 TeMpeRaTuRe / ma CONVeRTeR action Display shows Verify Ni sensor type and press OK TC.TYpe (ONLY IF SeNSOR = Ni and CH2.TYp = TeMp) Verify Thermocouple type and press OK (ONLY IF SeNSOR = TC and CH2.TYp = TeMp) Verify CJC type and press OK O.RaNGe (ONLY IF SeNSOR = TC and CH2.TYp = TeMp) Verify fixed output range for current output OuT.eRR Verify fixed output value on detected sensor error OuT.LO and press OK (ONLY IF CH2.TYp = TeMp, or IF I.RaNGe = 4-20 ma or 20-4 ma) Verify temperature for 0% output and press OK OuT.HI (ONLY IF CH2.TYp = TeMp) Verify temperature for 100% output and press OK ReSp (ONLY IF CH2.TYp = TeMp) Verify analogue output response time and press OK CH1.CaL Verify the use of applied process calibration values CH2.CaL for Channel 1 and press OK Verify the use of applied process calibration values paSSW. for Channel 2 and press OK Verify password and press OK SIL.OK Verify SIL mode within 1 second Version No. V5R0...
In addition, if a process calibration is taken into SIL-mode operation (refer to section 13.3 - advanced functions), it is mandatory that the accuracy of the device (and sensor, if applicable) are tested. 15 fault reaction and restart condition When the 9113 detects a fault the output will go to Safe State, in which the output will go to “de-energised”. If the fault is application-specific (cable error detection) the 9113 will restart when the fault has been corrected. For device faults there are 2 ways of bringing the device out of Safe State. 1. power cycle the device. 2. Bring the device out of SIL mode (choose “NO” in the menu point ”eN.SIL”), and set it back to SIL mode again (choose “YeS” in the menu point “eN.SIL” and verify the configuration).
Safety Manual 9113 TeMpeRaTuRe / ma CONVeRTeR 16 user interface 16.1 Scrolling help texts in display line 3 enter SIL setup [01] Set correct password [17] enter simulation mode [02] enter advanced setup menu? Select temperature input enter RaIL setup [03] Select current input perform process calibration enter language setup [04] Select 0-20 ma input range enter password setup Select 4-20 ma input range enter display setup [05] Select TC sensor type perform memory operations Select Ni sensor type Load saved configuration into 9113 Select pt sensor type [18] Save 9113 configuration in 4501 [06] Select pt10 sensor type adjust LCD contrast Select pt20 sensor type [19] Select pt50 sensor type adjust LCD backlight [20]...
Page 57
9113 TeMpeRaTuRe / ma CONVeRTeR Safety Manual 16.2 routing diagram If no key is activated for 1 minute, the display will return to the default state 1.0 power up without saving configuration changes. 1 Increase value / choose next parameter 2 Decrease value / choose previous parameter 3 accept the chosen value and proceed to the next menu Hold 3 Back to previous menu / return to menu 1.0 without saving 12 mA 100@C If SIL-locked directly to EN.SIL] 20-4 20-0 23mA 0000 CURR 4-20 4-20 0/3.5mA 9999 TEMP 0-20 0-20 NONE 0000 CURR 4-20 4-20 PASSW. ADV.SET I.RANGE O.RANGE OUT.ERR...
Page 58
Safety Manual 9113 TeMpeRaTuRe / ma CONVeRTeR 999.9 999.9 -199.9 -199.9 150.0 Configuration of CH2 OUT.LO OUT.HI RESP. To default state 1.0 Txt 14 Txt 15 Txt 15 identical to CH1 Version No. V5R0...
Safety Manual 9113 TeMpeRaTuRe / ma CONVeRTeR 17 Connections diagram Supply and power Rail status relay connections 31 32 33 34 91 92 93 94 95 N.C. Gnd. Gnd. +24 V error signal +24 V Inputs NC = no connection TC, internal *TC, RTD, 2-wire RTD, 3- / 4-wire CJC sensor CJC connector 41 42 43 44 41 42 43 44...
Page 61
displays Programmable displays with a wide selection of inputs and outputs for display of temperature, volume and weight, etc. Feature linearisation, scaling, and difference measurement functions for programming via PReset software. Ex interfaces Interfaces for analogue and digital signals as well as HART signals between sensors / I/P converters ®...