All manuals and user guides at all-guides.com
ENG
First turning on
Configuring the wireless connection of the corrector via the CM-WIFI BOX:
3.1.1. Connection type -> WIFI BOX Tree
3.1.2. WiFi ID -> rewrite it from the table on the boiler controller (Image: table on the boiler
controller)
3.1.3. Address code -> rewrite it from the table on the boiler controller
- IMPORTANT - the address code must be the same as selected corrector address!
3.1.4. Corrector address -> check that the same address is selected as on the boiler - if not, the
correct Address Code is not entered in the corrector.
3.1.5. Destination address -> if the corrector is connected directly to the CM-WiFi box, select WIFI
BOX here. If the corrector does not have a good enough signal to the CM-WiFi box, but has a good
signal to another corrector, select the address of that other corrector (>>>ADDR1, 2, 3...).
3.1.6. Get data -> START – if everything is configured correctly, the corrector will be connected to
the boiler / CM2K module (symbol in the upper right corner of the screen) and data from the boiler
control can be downloaded. If the corrector is not connected to the boiler / CM2K module, the
download will not be possible and you should check the correctness of the data entered.
After successful download of data from the boiler, it is necessary in menu 3.2. VIEWS join each
view of the corrector to each heating circuit and add a name if you want. If there is only one room
corrector in the heating system, in menu 3.2.1. Number of views is selected number 1. If there are
several room correctors (digital or analog) that you want to monitor/manage with this corrector, the
number of all correctors you want to monitor must be selected in this menu. Depending on the
number of selected views, in menu 3.2. Views the same number of button for editing a single view
appears (eg 3 views, View button A, B, C). In menu 3.2.2. View A can change the name of that view
(factory A) to eg 1st Floor or Living Room... (max. 30 symbols) and in the menu 3.2.2.2. Heating
circuit be sure to select the heating circuit to which that corrector joins.
After setting these basic parameters, the corrector is ready for use.
Wired
Router
Addr. 1
2
3
4
5
Technical instructions CSK-Touch
Image: table on the boiler controller
1
(only for authorized service persons);
Installation -> PIN -> CSK-Touch -> Info.
209
42dB
153
1 3
1. WiFi ID uniquely generated (or taken from WiFi-box)
38dB
427
2. CSK-Touch address on the boiler
3. Address code uniquely generated by the boiler for
8
each address
4. Corrector connection type with CM2K / boiler
5. Visibility of CSK-Touch
6
7
6. Signal quality
7. No. of packets downloaded from boiler controller
8. Reset packet counter