VENTING REQUIREMENTS:
•
Vent system must terminate to the outside
(Roof or side wall).
•
DO NOT terminate the vent system in an attic
or other enclosed area.
•
DO NOT use 4" (10.2 cm) laundry-type wall
caps.
•
Use metal/aluminum vent only. Rigid metal/
aluminum vent is recommended.
•
DO NOT use plastic vent.
•
Always keep the duct clean to ensure proper
airflow.
•
Calculate
the
installation:
1. Distance from the floor to the ceiling
2. Distance between the floor to the
countertop/stove
3. Distance between the cooking surface to
the range hood (recommend 24" to 30")
4. Height of hood and duct cover
For the most efficient & quiet operation:
•
A distance of 24" to 30" is recommended
between stove top and the bottom of range
hood.
•
It is recommended that the range hood be
vented vertically through the roof through 6"
(15.3 cm) or bigger round metal/aluminum
vent work.
•
The size of the vent should be uniform.
•
Use
no
more
•
Make sure there is a minimum of 24" (61 cm) of
straight vent between the elbows if more than one
elbow is used.
•
DO NOT install two elbows together.
•
The length of vent system and number of elbows
should be kept to a minimum to provide efficient
performance.
•
The vent system must have a damper. If roof or
wall cap has a damper, DO NOT use damper (if
supplied) on top of the range hood.
•
Use silver tape or duct tape to seal all joints in the
vent system.
•
Use caulking to seal exterior wall or roof opening
around the cap.
following
figures
than
three
90°
elbows.
HEIGHT & CLEARANCE:
before
5