Plumbing Hook-Up - EemaX LavAdvantage Guide D'installation Et Manuel Du Propriétaire

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

EX07200-121 Rev B
Remove the cover and fasten to the wall using the mounting holes at each corner of the back plate. Replace the cover.
FlowCo
LavAdvantage
The water heater is supplied with 3/8" brass compression fittings that are compatible with either copper or plastic pipes. Make sure
these fittings are used for this installation. Contact your Eemax representative for further information.
NEVER SUBSTITUTE THREADED PIPE FITTINGS USING PIPE DOPE OR TEFLON TAPE AND NEVER SOLDER
ANY PIPE CONNECTIONS WHILE ATTACHED TO THIS HEATER BECAUSE DAMAGE TO THE HEATER WILL
RESULT. DOING THIS WILL VOID THE WARRANTY!
Eemax strongly recommends that the heater be supplied directly from the main cold water trunk line when possible. This helps to
avoid a potential water flow interruption to the water heater which could lead to a failure of the heating element.
System Requirements:
• Minimum turn on flow rates are family dependent:
o
LavAdvantage: 0.2 GPM
o
AccuMix II: 0.3 GPM
o
FlowCo: vary by model (refer to the table below)
Turn On Flow Rate, GPM (LPM)
Base Model*
0.2
(0.76)
SPEX1812
SPEX2412
SPEX3012
SPEX3512
SPEX35
SPEX48
SPEX55
SPEX65
SPEX75
SPEX95
SPEX3208
SPEX4208
SPEX8208
SPEX3277
SPEX4277
SPEX60
SPEX80
SPEX90
SPEX100
*Special suffixed models (i.e. CA, etc.), will have identical temperature rises as their base model
For optimum performance, Eemax recommends the use of isolation valves (full flow ball type) on the inlet and outlet pipes and a 40
mesh Y-Strainer on the inlet of the heater.
Manufacturer's National Service Department | 400 Captain Neville Dr. Waterbury, CT 06705
Eemax® 800-543-6163 | EcoSmart® 877-474-6473 | Rheem® or Richmond® 800-374-8806
Information contained in this document is subject to change without notice.

3. PLUMBING HOOK-UP

0.25
0.3
0.4
(0.95)
(1.14)
(1.51)
AccuMix II
• Minimum/maximum working pressure: 30 PSI/150 PSI
• Optimal operating pressure range: 35 to 80 PSI
0.5
0.7
0.8
(1.89)
(2.65)
(3.03)
5

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Accumix iiFlowco

Table des Matières