Lavadvantage Unit Operation; Advanced Functions - EemaX LavAdvantage Guide D'installation Et Manuel Du Propriétaire

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

EX07200-121 Rev B
FLOW RATE, GPM (LPM)
BASE MODEL*
0.2
(0.76)
TEMPERATURE RISE, °F (°C)
SPEX1812
61
(34)
SPEX2412
82
(46)
SPEX3012
-
-
SPEX3512
-
-
SPEX35
-
-
SPEX48
-
-
SPEX55
-
-
SPEX65
-
-
SPEX75
-
-
SPEX95
-
-
SPEX3208
-
-
SPEX4208
-
-
SPEX8208
-
-
SPEX3277
-
-
SPEX4277
-
-
SPEX60
-
-
SPEX80
-
-
SPEX90
-
-
SPEX100
-
-
Note: the values shown above are only for comparison purposes.
*Special suffixed models (i.e. CA, etc.), will have identical temperature rises as their base model
"-"Flow rate below turn on flow for this model
Factory temperature setpoints/maximum adjustable range:
Suffix
<4kW
Base Model
>4kW
S (Sanitation)
ML (Multi-Lavatory)
EE (Emergency Eyewash)
CHANGING SETPOINT TEMPERATURE
To INCREASE temperature, tap the "+" button repeatedly, or hold the "+" down to INCREASE the temperature quickly. To DECREASE
temperature, tap the "–" button repeatedly, or hold the "–" down to DECREASE the temperature quickly.

ADVANCED FUNCTIONS

With the display showing the current setpoint temperature, press BOTH "+" AND "–" buttons simultaneously for 3 seconds.
Screen Info
Title
Flow Rate
FLO
Inlet temperature
IN
Outlet temperature
OUT
Power Factor
PF
Software Revision
SR
Hold "-" to display the current screen title.
Press "+" to advance to the next screen.
Holding both "+" and "–" at any time for 3 seconds returns the display to the temperature set point, or just let the heater return to
set point display on its own after a period of time.
Manufacturer's National Service Department | 400 Captain Neville Dr. Waterbury, CT 06705
Eemax® 800-543-6163 | EcoSmart® 877-474-6473 | Rheem® or Richmond® 800-374-8806
Information contained in this document is subject to change without notice.
0.25
(0.95)
0.3
(1.14)
49
(27)
41
(23)
66
(37)
55
(31)
82
(46)
68
(38)
-
-
80
(44)
-
-
80
(44)
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
82
(46)
68
(38)
-
-
-
-
-
-
-
-
82
(46)
68
(38)
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-

6. LAVADVANTAGE UNIT OPERATION

Default
Minimum
Maximum
Setpoint
Setpoint
Setpoint
(°F)
(°F)
(°F)
105
70
140
120
120
70
180
110
70
110
90
70
90
Units
Description
GPM or LPM
Current water flow rate through unit
°F or °C
Cold water temperature
°F or °C
Hot water temperature
%
How hard the heater is working
-
For Technical Support assistance
0.4
(1.51)
0.5
(1.89)
31
(17)
25
(14)
41
(23)
33
(18)
51
(28)
41
(23)
60
(33)
48
(27)
60
(33)
48
(27)
82
(46)
66
(37)
-
-
75
(42)
-
-
-
-
-
-
-
-
-
-
-
-
51
(28)
41
(23)
70
(39)
56
(31)
-
-
-
-
51
(28)
41
(23)
70
(39)
56
(31)
-
-
82
(46)
-
-
-
-
-
-
-
-
-
-
-
-
0.7
(2.65)
0.8
(3.03)
18
(10)
15
(8)
23
(13)
20
(11)
29
(16)
26
(14)
34
(19)
30
(17)
34
(19)
30
(17)
47
(26)
41
(23)
54
(30)
47
(26)
63
(35)
55
(31)
73
(41)
64
(36)
-
-
81
(45)
29
(16)
26
(14)
40
(22)
35
(19)
81
(45)
71
(39)
29
(16)
26
(14)
40
(22)
35
(19)
59
(33)
51
(28)
78
(43)
68
(38)
-
-
77
(43)
-
-
-
-
1
(3.79)
12
(7)
16
(9)
20
(11)
24
(13)
24
(13)
33
(18)
38
(21)
44
(24)
51
(28)
65
(36)
20
(11)
28
(16)
57
(32)
20
(11)
28
(16)
41
(23)
55
(31)
61
(34)
68
(38)
11