Reset to Factory Default Settings

If the camera no longer functions as expected, you can choose to
restore the camera to its factory default settings.
Use the firmware revert button to reset the camera.
NOTE: Be careful not to scratch the dome bubble.
Figure: The firmware revert microswitch between the status LEDs.
1.
Ensure the camera is powered on.
2.
Remove the dome cover by loosening the 4 tamper-proof
screws that fix the cover to the base. The tamper resistant
key included with the dome camera can be used to loosen
the screws
3.
Using a straightened paperclip or similar tool, gently press
and hold the firmware revert microswitch for two seconds.
4.
Re-install the dome cover.
Caution — Do not apply excessive force. Inserting the tool
too far will damage the device.