RS485 Setting
The 4-bit DIP switch is used for
RS485 termination.
BP 1
ON
Switch
position
OFF
BP 2
BP 3 BP 4
ON ON ON
Switch
position
OFF OFF OFF
Notes:
• Defaults are marked with *.
• BP stands for Bit Position.
• Full duplex is not available in a daisy chain connec-
tion. (Panasonic system controllers only)
5. Mounting the camera
(1) Aim the "START" arrow at the bent portion of the
leaf spring.
Bending
SW2
ON
1
2
3
4
4-bit DIP SW
Function
Termination ON
Termination OFF
*
Function
Half duplex (2 line)
Full duplex (4 line)
Leaf Spring
(2) Be sure to hook the fall prevention wire into the
bracket.
*
(3) Fix the camera to the upper base.
• Move the camera up so that its guide pins fit
into the guide holes of the upper base.
• Turn the camera counter-clockwise to the
end, viewed from the bottom.
• Fasten 3 screws.
-50-
Fall Prevention
Wire
x3 Screws
Upper Base
Enclosure