Performance Data Sheet
SmartWater
The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible
limit for water leaving the system as specified in NSF/ANSI Standard 42 and Standard 53. System tested and certified by NSF International against
NSF/ANSI Standard 42 and Standard 53 for the reduction of substances listed below.
Capacity 300 Gallons (1,135 Liters).
Substance Tested
for Reduction
Av
Chlorine Taste and Odor
2.0 mg/L
Nominal Particulate
7,833,333 pts/mL
Cyst*
101,000 cysts/L
Asbestos
47 MF/L
Atrazine
0.009 mg/L
Benzene
0.016 mg/L
Carbofuran
0.08 mg/L
Endrin
0.007 mg/L
Lead @ pH 6.5
0.152 mg/L
Lead @ pH 8.5
0.148 mg/L
Lindane
0.002 mg/L
Mercury @ pH 6.5
0.0058 mg/L
Mercury @ pH 8.5
0.0061 mg/L
P-Dichlorobenzene
0.222 mg/L
Tetrachloroethylene
0.015 mg/L
Toxaphene
0.015 mg/L
2,4-D
0.218 mg/L
*Based on the use of Cryptosporidium parvum oocysts.
The following pharmaceutical reduction claims have not been certi ed by NSF International or the state of California.
Claims tested and veri ed by independent laboratory:
Contaminant
Reduction
Av
Atenolol
978 ng/L
Fluoxetine
907 ng/l
Ibuprofen
885 ng/L
Progesterone
1097 ng/L
Trimethoprim
415 ng/L
Application Guidelines/Water Supply Parameters
Service Flow
0.5 gpm (21.9 lpm)
Water Supply
Potable Water
It is essential that the manufacturer's recommended installation, maintenance and filter replacement requirements be carried out for the product to perform as advertised.
See Installation Manual for Warranty information.
Note:
While the testing was performed under standard laboratory conditions,
actual performance may vary.
Replacement Cartridge: MWF. For estimated costs of replacement elements
please call 1-800-626-2002 or visit our website at www.geapplianceparts.com.
WARNING
To reduce the risk associated with ingestion of contaminants:
• Do not use with water that is microbiologically unsafe or of unknown quality
without adequate disinfection before and after the system. Systems cert ed
for cyst reduction may be used on disinfected water that may contain lterable
cysts. EPA Establishment Number 10350-MN-005.
For conditions of use, health claims certified by the California Department of Public
Health, and replacements, see performance data sheet. California Department
of Public Health Certification #05-1698. The contaminants or other substances
removed or reduced by this water filter are not necessarily in all users' water.
Tested and cer ed by NSF International
against NSF/ANSI Standard 42 and
Standard 53 in model GE MWF for the
reduction of the claims speci d on the
performance data sheet.
REPLACEMENT
ELEMENT
Filtration System GE MWF Cartridge
™
Contaminant Reduction Determined by NSF testing.
Challenge Concentration
2.0 mg/L ± 10%
At least 10,000 particles/mL
Minimum 50,000 cysts/L
r
gr
0.009 mg/L ± 10%
0.015 mg/L ± 10%±
0.08 mg/L ± 10%
0.006 mg/L ± 10%
0.15 mg/L ± 10%
0.15 mg/L ± 10%
0.002 mg/L ± 10%
0.006 mg/L ± 10%
0.006 mg/L ± 10%
0.225 mg/L ± 10%
0.015 mg/L ± 10%
0.015 mg/L ± 10%
0.210 mg/L ± 10%
Challenge Concentration
N/A
N/A
N/A
N/A
N/A
Average Product
Avg %
Water
Reduction
Concentration
97.5%
0.05 mg/L
99.7%
18,617 pts/mL
99.99%
1 cyst/L
rs
>99%
94.5%
0.0005 mg/L
96.7%
0.0005 mg/L
98.7%
0.001 mg/L
97.1%
0.0002 mg/L
99.3%
0.001 mg/L
99.3%
0.001 mg/L
99.0%
0.00002 mg/L
93.2%
0.0004 mg/L
93.2%
0.0004 mg/L
99.8%
0.005 mg/L
96.7%
0.0005 mg/L
93.2%
0.001 mg/L
99.5%
0.0009 mg/L
Average Product
Avg %
Water
Reduction
Concentration
99.5%
5.0 ng/L
99.4%
5.4 ng/L
94.1%
52.3 ng/L
99.5%
5.0 ng/L
99.5%
2.0 ng/L
Water Pressure
Water Temperature
NOTICE
To reduce the risk associated with property damage due to water leakage:
• Read and follow use instructions before installation and use of this system.
• Installation and use MUST comply with all state and local plumbing codes.
• Do not install if water pressure exceeds 120 psi (8.2 bar). If your water pressure
exceeds 80 psi, you must install a pressure-limiting valve. Contact a plumbing
professional if you are uncertain how to check your water pressure.
• Do not install where water hammer conditions may occur. If water hammer
conditions exist you must install a water hammer arrester. Contact a plumbing
professional if you are uncertain how to check for this condition.
• Do not install on hot water supply lines. The maximum operating water
temperature of this lter system is 100º F (38º C).
• Protect lter from freezing. Drain lter when temperatures drop
below 33ºF (0.6ºC).
•
rated capacity, or sooner if a noticeable reduction in
Max Permissible
Product Water
NSF Reduction
Concentration
Requirements
N/A
N/A
N/A
N/A
0.003 mg/L
N/A
0.005 mg/L
N/A
0.04 mg/L
N/A
0.002 mg/L
N/A
0.010 mg/L
N/A
0.010 mg/L
N/A
0.0002 mg/L
N/A
0.002 mg/L
N/A
0.002 mg/L
N/A
0.075 mg/L
N/A
0.005 mg/L
N/A
0.003 mg/L
N/A
0.07 mg/L
N/A
Max Permissible
Product Water
NSF Reduction
Concentration
Requirements
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
40-120 psi (2.8-8.2 bar)
33°F-100°F (0.6°C-38°C)
must be replaced every 6 months at the
w rate occurs.
NSF
Test Report
J-00077703
J-00077704
J-00100036
J-00077707
J-00077708
J-00077717
J-00077718
J-00100039
J-00077722
J-00077723
J-00077726
J-00100037
J-00092355
J-00077729
J-00082184
J-00077730
J-00085470
NSF
Test Report
J-00121587
J-00121587
J-00121588
J-00121589
J-00121587
43