Performance Data Sheet - GE Monogram ZWE23ESHSS Manuel Du Propriétaire

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Performance Data Sheet

Model: GE RPWFE
Use Replacement Cartridge RPWFE.
The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible
limit for water leaving the system as specified in NSF/ANSI Standard 42 and Standard 53. System tested and certified by NSF International against
NSF/ANSI Standard 42 and Standard 53 for the reduction of substances listed below.
Capacity 170 Gallons (643.5 Liters).
Substance Tested
for Reduction
Average Influent
Chlorine Taste and Odor
Nominal Particulate
Class I, , ≥0.5 to < 1.0 μm 7,633,333 pts/mL
Asbestos
Atrazine
Benzene
Carbofuran
Cyst*
104,750 cysts/L
Lead pH @6.5
Lead pH @8.5
Mercury @ pH 6.5
Mercury @ pH 8.5
Lindane
P-Dichlorobenzene
Toxaphene
2, 4-D Reduction
VOC
*Based on the use of Cryptosporidium parvum oocysts.
The following pharmaceutical reduction claims have not been certified by NSF International. Claims tested and verified
by independent laboratory:
Substance
Reduction
Average Influent
Atenolol
Fluoxetine
Ibuprofen
Progesterone
Trimethoprim
Application Guidelines/Water Supply Parameters
Service Flow
Water Supply
It is essential that the manufacturer's recommended installation, maintenance and filter replacement requirements be carried out for the product to perform as advertised.
See Installation Manual for Warranty information.
Note:
While the testing was performed under standard laboratory conditions,
actual performance may vary.
Replacement Cartridge: RPWFE. For estimated costs of replacement elements
please call 1-800-626-2002 or visit our website at www.geapplianceparts.com.
WARNING
To reduce the risk associated with ingestion of contaminants:
Do not use with water that is microbiologically unsafe or of unknown quality
without adequate disinfection before and after the system. Systems certified
for cyst reduction may be used on disinfected water that may contain filterable
cysts. EPA Establishment Number 070595-MEX-001.
NOTICE
To reduce the risk of water leakage or flooding, and to ensure optimal filter
performance:
Read and follow use instructions before installation and use of this system.
MUST comply with all state and local plumbing codes.
Tested and certified by NSF International
against NSF/ANSI Standard 42 and Standard 53
in model GE RPWF and GE RPWFE for the
reduction of the claims specified on the
performance data sheet.
REPLACEMENT
ELEMENT
18
Contaminant Reduction Determined by NSF testing.
NSF specified
Challenge Concentration
2.0 mg/L
2.0 mg/L ± 10%
At least 10,000 particles/mL
7
8
10
to 10
fibers/L; fibers
109 MFL
greater than 10μm in length
0.009 mg/L
0.009 mg/L ± 10%
0.016 mg/L
0.015 mg/L ± 10%
0.08 mg/L
0.08 mg/L ± 10%
Minimum 50,000 cysts/L
0.140 mg/L
0.15 mg/L ± 10%
0.158 mg/L
0.15 mg/L ± 10%
0.006 mg/L
0.006 mg/L ± 10%
0.006 mg/L
0.006 mg/L ± 10%
0.002 mg/L
0.002 mg/L ± 10%
0.222 mg/L
0.225 mg/L ± 10%
0.015 mg/L
0.015 mg/L ± 10%
0.218 mg/L
0.210 mg/L±10%
0.278 mg/L
0.300 mg/L ± 10%
NSF specified
Challenge Concentration
1088 ng/L
N/A
845 ng/L
N/A
898 ng/L
N/A
945 ng/L
N/A
403 ng/L
N/A
0.5 gpm (1.89 lpm)
Potable Water
Average Product
Max Permissible
Avg %
Water
Reduction
Concentration
97.4%
0.05 mg/L
99.0%
71,850 pts/ml
99.99%
<1 MFL
94.4%
0.0005 mg/L
96.4%
0.001 mg/L
98.8%
0.001 mg/L
99.99%
3 cyst/L
99.3%
0.001 mg/L
98.3%
0.002 mg/L
91%
0.0003 mg/L
88.3%%
0.0007 mg/L
99%
0.00002 mg/L
99.8%
0.0005 mg/L
93.5%
0.001 mg/L
99.9%
0.0001 mg/L
97.7%
0.0015 mg/L
Avg %
Average Product Water
Reduction
Concentration
99.5%
5.0 ng/L
99.4%
5.0 ng/L
98.8%
9.9 ng/L
99.4%
5.5 ng/L
99.5%
2.0 ng/L
Water Pressure
Water Temperature
Do not install if water pressure exceeds 120 psi (827 kPa). If your water pressure
exceeds 80 psi, you must install a pressure-limiting valve. Contact a plumbing
professional if you are uncertain how to check your water pressure.
Do not install where water hammer conditions may occur. If water hammer
conditions exist you must install a water hammer arrester. Contact a plumbing
professional if you are uncertain how to check for this condition.
Do not install on hot water supply lines. The maximum operating water
temperature of this filter system is 100º F (38º C).
Protect filter from freezing. Drain filter when temperatures drop
below 33ºF (0.6ºC).
a noticeable reduction in water flow rate.
lead to reduced filter performance and cracks in the filter housing, causing water
leakage or flooding.
Product Water
NSF Reduction
Concentration
Requirements
N/A
≥50%
N/A
≥85%
N/A
≥99%
0.003 mg/L
N/A
0.005 mg/L
N/A
0.04 mg/L
N/A
N/A
≥99.95%
0.010 mg/L
N/A
0.010 mg/L
N/A
0.002 mg/L
N/A
0.002 mg/L
N/A
0.0002 mg/L
N/A
0.075 mg/L
N/A
0.003 mg/L
N/A
0.07 mg/L
N/A
N/A
≥95%
Max Permissible
Product Water
Concentration
N/A
N/A
N/A
N/A
N/A
25-120 psi (172– 827 kPa)
33º F - 100º F (0.6º C - 38º C)
NSF
Test Report
J-00102044
J-00106249
J-00102069
J-00102058
J-00102065
J-00102059
J-00102057
J-00102052
J-00102053
J-00102054
J-00104087
J-00102063
J-00102067
J-00102061
J-00102064
J-00102070
NSF
Test Report
J-00103221
J-00103221
J-00103726
J-00103727
J-00103221
RPWFE

Publicité

Table des Matières
loading

Table des Matières