Instructions

3.1

Input Panel

[1] Chassis ground
Chassis ground is connected to the inverter AC outlet ground.
[2] Remote control port
Some Phocos solar charge controllers are designed to shut off the inverter when the
controller senses Low Voltage Disconnect (LVD). The controller must be connected to the
inverter remote control port, and the inverter main switch must be set to remote mode.
A modular 6p4c type connector (included in the scope of delivery of the charge controller)
is available with compatible Phocos controllers (CXNsolid and CMLsolid) to control any
inverter of the Phocos PSW series, by the LVD function of the charge controller. The inverter
will not be switched off at load over current.
[3] Cooling fan
Do not obstruct cooling fan. Allow at least
5cm for airflow.
3.2

Output Panel

[1] Main Switch
Off, On, and Remote settings
www.phocos.com
[4] Input battery connectors
Red (+) and Black (-)
[2] USB output port
Rated for 5 V, 2.1 A