INSTALLATION INSTRUCTIONS
CAUTION:
SERVICE PANEL BEFORE STARTING INSTALLATION.
SECTION 1
Preparing the Exhaust Fan
1.
Unpack fan from the carton and confirm that all pieces are present. In addition to the
exhaust fan you should have:
1 - Grill
1 - Light Assembly
1 - Damper Assembly (attached)
4 - Mounting Rails
1 - Lamp
1 - Instruction/Safety Sheet
2.
Choose the location for your fan. To ensure the best air and sound performance, it
is recommended that the length of ducting and the number of elbows be kept to a
minimum, and that insulated hard ducting be used Larger duct sizes will reduce noise
and airflow restrictions. This fan will require at least 8" of clearance in the ceiling or wall,
and will mount through drywall up to 3/4" thick. The
fan mounts between 16" or 24" on center joists using
the 4 provided mounting rails.
3.
Select the most convenient electrical knockout and
remove using a straight-blade screw driver and install
an approved electrical connector (Figure 1).
4.
No additional vibration deadening materials are needed
for this fan.
SECTION 2
New Construction
1.
Install the rails into the mounting channel on the housing. Center the mounting channel in
the slots on the housing, then from inside the housing tighten the mounting channel screws
so the channel is securely in place. Position the housing next to the joist. Line up housing
so that it will be flush with the finished ceiling. Secure the ends of the rails with screws or
nails (not included) to the joists and slide the housing into the final position (Figure 2).
Housing
Joist
Figure 2
SECTION 3
Existing Construction
1.
Set housing in position between the joist and trace an outline onto the ceiling material
(Figure 3). Set housing aside and cut opening, being careful not to cut or damage any
electrical or other hidden utilities. Install the rails into the mounting channel on the
housing. Center the mounting channel in the slots on the housing, then from inside
the housing tighten the mounting channel screws so the channel is securely in place.
Position the housing in the previously cut hole so that it is flush with the finished ceiling.
Secure the ends of the rails to the joists (Figure 2).
Joist
Figure 3
A210952014 Rev. O 11-18
MAKE SURE POWER IS SWITCHED OFF AT
Figure 1
Mounting Rails
SECTION 4
Ducting
NOTE: 4" OR LARGER RIGID DUCT IS RECOMMENDED FOR BEST PERFORMANCE.
CAUTION:
NATIONAL BUILDING CODES.
NOTE: The ducting from this fan to the outside of the building has a strong effect on the air
flow, noise and energy use of the fan. Use the shortest, straightest duct routing possible
for best performance, and avoid installing the fan with smaller ducts than recommended.
Insulation around the ducts can reduce energy loss and inhibit mold growth. Fans installed
with existing ducts may not achieve their rated air flow.
Connect the ducting to the fan's duct collar (Figure 4). Secure in place using tape
1.
or screw clamp. Always duct the fan to the outside through a wall or roof cap. It is
recommended that low restriction termination fittings be used.
Ducting
Figure 4
2.
Ensure duct joints and exterior penetrations are sealed with caulk or other similar
material to create an air-tight path to minimize building heat loss or gain and to reduce
the potential for condensation. Place/wrap insulation around duct and/or fan in order to
minimize possible condensation buildup within the duct, as well as building heat loss or
gain (Figure 5).
Insulation*
(place around and
over Fan Housing
Power Cable*
Seal gaps
around Housing
Figure 5
SECTION 5
Wiring
CAUTION:
SERVICE PANEL BEFORE STARTING INSTALLATION.
CAUTION:
IN ACCORDANCE WITH LOCAL CODES, ORDINANCES, OR NATIONAL
ELECTRICAL CODE. IF YOU ARE UNFAMILIAR WITH METHODS OF INSTALLING ELECTRICAL
WIRING, SECURE THE SERVICES OF A QUALIFIED ELECTRICIAN.
NOTE: This unit includes a side access panel for wiring that does not require the removal of
the fan's blower assembly. If you choose to wire the unit from the inside, you will need to
remove the blower assembly and internal wiring compartment. Both methods are equally
effective.
1a. External Wire Compartment: Remove the wire compartment cover screw and place
cover in a secure place (Figure 6).
www.airkinglimited.com
ALL DUCTING MUST COMPLY WITH LOCAL AND
Duct
Collar
Keep duct
Fan Housing
runs short
or
Round
Duct*
Round
Elbows*
Seal duct joints
with tape
MAKE SURE POWER IS SWITCHED OFF AT
ALL ELECTRICAL CONNECTIONS MUST BE MADE
Roof Cap*
(with built-in
damper)
Wall Cap*
*Purchase separately