General

Use the information in this section to install a NLL Series
Narrow Display Light.
WARNING
ELECTRIC SHOCK HAZARD:
• Unit is not weatherproof. Locate unit indoors where the
ambient air temperature is a minimum of 70°F (21°C).
• Do not install unit above a steam table or other steam
generating appliance.
1. Remove the unit from the carton.
NOTE: To prevent delay in obtaining warranty coverage, complete
online warranty registration. See the IMPORTANT
OWNER INFORMATION section for details.
2. Remove tape and protective packaging from all surfaces
of the unit.
3. Install the unit in the desired location.
a. For under-shelf installation, refer to "Angle Bracket
Installation" in this section.
b. For countertop installation, refer to "Tubular Stand
Installation" in this section.
NOTE: LED display lights cannot be installed over a steam
table.
Angle Bracket Installation
Use the following procedure to install the unit using mounting
brackets.
WARNING
ELECTRIC SHOCK HAZARD: Do not install unit above a
steam table or other steam generating appliance.
Do not install unit on or below a radiant-heating ceiling.
1. Attach the included mounting brackets to each end of the
unit using the screws provided.
2. Fasten the mounting brackets on each end of the unit
to the underside of a shelf or other overhead mounting
surface using appropriate fasteners (not supplied by
Hatco).
• Make sure the unit is facing the desired direction with
the power cord on the proper side before fastening the
unit to the overhead surface.
Under-Shelf Installation
3. Plug the unit into an appropriate electrical receptacle.
Form No. NLLM-1216
CAUTION
Mounting
Bracket
Shelf
Tubular Stand Installation
Use the following procedure to install the unit using tubular
stands.
ELECTRIC SHOCK HAZARD: Do not install unit above a
steam table or other steam generating appliance.
Do not install unit on or below a radiant-heating ceiling.
Tubular stands are available in aluminum, Designer colors, or
gloss finishes in heights from 10"–16" (254–406 mm).
NOTE: Tubular stands are not field retrofittable.
NOTE: If wiring is to be concealed, a 1" (25 mm) diameter hole
must be provided in the mounting surface under the
stand containing the wiring conduit.
1. Position the unit upside-down on a flat surface.
NOTE: Units for this application are supplied with the conduit
attached to one side of the unit. Conduit should not be
removed.
2. If applicable, prepare the mounting surface for concealing
wiring.
a. Cut a 1" (25 mm) diameter hole into the mounting
surface at the appropriate location.
NOTE: The distance between the center of the two stands is
found by subtracting 1-15/16" (49 mm) from the overall
width of the strip heater.
b. Route the flexible conduit through the tubular stand and
into the mounting surface.
2"
(51 mm)
Mounting Hole Distance =
Width (A) – 1-15/16" (49 mm)
Countertop Conduit Hole Dimension
3. Secure the conduit-side stand to the unit using the screws
supplied.
4. Align the opposite-side stand with the mounting holes at
the other end of the unit and secure the stand to the unit
using the screws supplied.
5. Secure the stands to the mounting surface.