INSTALLATION MANUAL
CAA - CBB
Self-contained Keypads - braille keys
illumination. The green led lights on
to confi rm the programming.
4. Press 2 for output time of relay 2
- Green LED lights on for 1 second.
- Enter the duration in seconds.
E.g. : From 01 for 1 second to 99
for 99 seconds or enter 00 for a permanent
illumination. The green led lights on
to confi rm the programming.
5. Press 3 for output time of relay 3
- Green LED lights on for 1 second.
- Enter the duration in seconds.
6. P ress # to exit from the programming
mode.
T he red LED lights off to confi rm that the keypad
is in stand-by operating mode.
Red LED fl ashing 4 times indicates
a data computing error.
F. Resetting the master code
- In normal operation, place a jumper at P2
- Green LED lights on to confi rm entry
in programming mode.
2. Enter #0 for the key-in keypad time.
- Green LED lights on for 1 second.
- A beep is emitted.
- Wait for the green LED to light off.
- Remove the jumper.
- The master code is again 1 2 3 4 5 6
in 6 digits, 1 2 3 4 5 in 5 digits
or 1 2 3 4 in 4 digits.
G. Changing the code by the user
T o enable the function programming the code
by the user place jumper on P3. Remove the
jumper to disable the function.
1. Enter the old user code.
- The relay is activated.
- Green LED lights on.
2. Enter the 2-digit sub master code
- The red LED lights on to authorise
the modifi cation.
3. Enter the new user code.
- Green LED lights on for 1 second
to confi rm the new code.
- The red LED lights off.
Check the new user code to be sure
of the modifi cation.
H. S etting a sub master code
1. Enter the master code twice.
- For the fi rst use the factory master code
is: 1 2 3 4 5.
- The red LED's light on to confi rm entry
in programming mode.
2. P ress 7 to input modifi cation digits
for group 1 user codes.
- Green LED lights on for 1 second.
- Enter the two digits of the modifi cations.
3. P ress 8 to input modifi cation digits
for group 2 user codes.
- Green LED lights on for 1 second.
- Enter the two digits of the modifi cations.
4. P ress 9 to input modifi cation digits
for group 3 user codes.
- Green LED lights on for 1 second.
- Enter the two digits of the modifi cations.
5. P ress # to exit from the programming mode.
T he red LED lights off to confi rm that the keypad
is in stand-by operating mode.
I. Programming the audible signal
The audible signal is always audible during
programming. It is also audible on a command
to open, following the recognition of a code.
By default, when the opening code is entered,
no "key" beep is audible. It is possible to authorise
key beeps by proceeding as follows:
1. Enter the master code twice.
- For the fi rst use, the factory
master code is: 1 2 3 4 5.
- Red LED lights on to confi rm
entry in programming mode.
2. Press .
- One beep is emitted.
Press 0 to disable the audible signal
during a keypress.
EN
-
cdvi.com
17