CDVI Digicode CAA Manuel D'installation page 17

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

  INSTALLATION MANUAL
CAA - CBB
Self-contained Keypads - braille keys
illumination. The green led lights on
to confi rm the programming.
4. Press    2 for output time of relay 2 
- Green LED lights on for 1 second.
- Enter the duration in seconds.
E.g. : From 01 for 1 second to 99
for 99 seconds or enter 00 for a permanent
illumination. The green led lights on
to confi rm the programming.
5. Press    3 for output time of relay 3 
- Green LED lights on for 1 second.
- Enter the duration in seconds.
6.   P ress # to exit from the programming 
mode.
 
  T he red LED lights off to confi rm that the keypad
is in stand-by operating mode.
Red LED fl ashing 4 times indicates
a data computing error.
F. Resetting the master code
- In normal operation, place a jumper at P2
- Green LED lights on to confi rm entry
in programming mode.
2. Enter #0 for the key-in keypad time.
- Green LED lights on for 1 second.
- A beep is emitted.
- Wait for the green LED to light off.
- Remove the jumper.
- The master code is again 1 2 3 4 5 6
in 6 digits, 1 2 3 4 5 in 5 digits
or 1 2 3 4 in 4 digits.
G.    Changing the code by the user
  T o enable the function programming the code 
by the user place jumper on P3. Remove the 
jumper to disable the function.
1. Enter the old user code. 
- The relay is activated.
- Green LED lights on.
2. Enter the 2-digit sub master code 
- The red LED lights on to authorise
the modifi cation.
3.  Enter the new user code. 
- Green LED lights on for 1 second
to confi rm the new code.
- The red LED lights off.
Check the new user code to be sure 
of the modifi  cation.
H.  S etting a sub master code
1. Enter the master code twice.
- For the fi rst use the factory master code
is: 1 2 3 4 5.
- The red LED's light on to confi rm entry
in programming mode.
2.   P ress    7 to input modifi  cation digits 
for group 1 user codes. 
- Green LED lights on for 1 second.
- Enter the two digits of the modifi cations.
3.   P ress    8 to input modifi  cation digits 
for group 2 user codes. 
- Green LED lights on for 1 second.
- Enter the two digits of the modifi cations.
4.   P ress    9 to input modifi  cation digits 
for group 3 user codes. 
- Green LED lights on for 1 second.
- Enter the two digits of the modifi cations.
5.   P ress # to exit from the programming mode.
 
  T he red LED lights off to confi rm that the keypad
is in stand-by operating mode.
I. Programming the audible signal
The audible signal is always audible during
programming. It is also audible on a command
to open, following the recognition of a code.
By default, when the opening code is entered,
no "key" beep is audible. It is possible to authorise
key beeps by proceeding as follows:
1. Enter the master code twice.
- For the fi rst use, the factory
master code is: 1 2 3 4 5.
- Red LED lights on to confi rm
entry in programming mode.
2. Press      .
- One beep is emitted.
Press 0 to disable the audible signal
during a keypress.