MODEL 350
Vibratone® Electro-Mechanical Horn
Installation and Maintenance
Instructions
Limited Warranty: This product's limited warranty
can be found at www.fedsig.com/SSG-Warranty.
Messages to Installers and Users
should be installed to code by a licensed electrician
and follow all safety instructions. Failure to do so
may result in property damage, serious injury, or
death.
Read and understand instructions before
installing or operating the equipment.
SHOCK HAZARD - To avoid electrical shock
hazards, do not connect wires when power is
applied.
Optimum sound distribution will be severely
reduced if any objects are in front of the horn.
Ensure that the front of the horn is clear of any
obstructions.
All effective warning sounders produce loud
sounds that may cause, in certain situations,
permanent hearing loss. Take appropriate
precautions, such as hearing protection. The
device should be installed far enough away
from potential listeners to limit their exposure
while still maintaining its effectiveness. The
OSHA Code of Federal Regulations 1910.95
Noise Standard provides guidelines that may
be used regarding permissible noise exposure
levels.
After installation, test the system to ensure
that it is operating properly.
Overview: The Model 350 horn is a very loud
electro-mechanical device that produces a horn
tone by vibration of a diaphragm. This horn is
capable or reproducing coded blasts or sustained
tone. The horn has a duty cycle of five minutes on,
five minutes off.
Unpacking the Device: After unpacking the device,
examine it for damage and verify the parts. See
Table 1 for the Carton Contents List. If a part is
This product
missing or appears damaged, do not attempt to
install. Contact Federal Signal Customer Support at
+1 708-587-3587 or iordersup@fedsig.com.
Qty
Mounting the Device
The horn may be directly mounted to a standard
4-inch square electrical box or may be mounted
using various Federal Signal accessories
(purchased separately).
Outlet Box Mounting
To mount the horn to a wall or other flat vertical
surface:
1.
2.
3.
4.
Table 1 Carton Contents List
Description
1
350 Horn
2
8-32 x 1-5/8" oval head screws
2
10-32 x 5/8" oval head tapping screws
1
10-32 x 3/8" hex head tapping screw
1
10-32 x 3/8" hex socket head set screw
Mount a 4-inch square electrical box to the
mounting surface with appropriate user
supplied hardware.
Connect the wires per the Electrical
Connections section below.
Mount the horn to the box using the two 8-32
by 1-5/8-inch screws provided.
Install the two 10-32 by 5/8-inch tapping
screws into the two unused screw openings
on the horn. See Figure 1.

Publicité

Table des Matières
loading

Sommaire des Matières pour Federal Signal Vibratone 350

  • Page 1 This product missing or appears damaged, do not attempt to should be installed to code by a licensed electrician install. Contact Federal Signal Customer Support at and follow all safety instructions. Failure to do so +1 708-587-3587 or iordersup@fedsig.com. may result in property damage, serious injury, or death.
  • Page 2: Flush Mounting

    10-32 by 5/8-inch tapping screws into the Weatherproof surface mounting requires the use of two unused screw openings on the horn. See Federal Signal Model WB Weatherproof Back Box Figure 2. accessory. To mount the horn in this manner: Mount the Weatherproof Back Box to the...
  • Page 3 290A2450-06 290A4699 Recessed Weatherproof Panel Mounting Recessed weatherproof panel mounting requires the use of the Federal Signal Panel Mount Gasket Kit (part number K8435666A). To mount the horn in this manner: Make a cutout in the panel per the template provided with Panel Mount Gasket Kit K8435666A.
  • Page 4: Electrical Connections

    Use a 3/32-inch hex key wrench to rotate the set screw clockwise until the desired sound level is reached. 2645 Federal Signal Drive, University Park, Illinois 60484 Additional translations available at signaling.fedsig.com Traducciones adicionales disponibles en signaling.fedsig.com Customer Support 1-800-344-4634+1-708-534-4756, iordersup@fedsig.com Technical Support 1-800-755-7621+1-708-587-3587, signalsupport@fedsig.com...
  • Page 5: Montage De L'appareil

    Tous les résonateurs d’avertissement efficaces électrique carré standard de 4 pouces ou peut être produisent des sons puissants, qui peuvent monté à l’aide de divers accessoires Federal Signal entraîner, dans certaines situations, une perte permanente de l’ouïe. Prenez les précautions (achetés séparément).
  • Page 6: Montage Semi-Encastré

    Le montage mural semi-encastré nécessite l’utilisation d’accessoires pour plaque de montage semi-encastrée de Federal Signal modèle SF. Cet accessoire se monte sur un anneau en plâtre à deux gangs fourni par l’utilisateur et fixé à un boîtier électrique carré encastré...
  • Page 7: Montage Avec Panneau Résistant Aux Intempéries

    Le montage avec panneau résistant aux intempéries nécessite l’utilisation de l’accessoire de modèle TR de Federal Signal. Pour monter l’avertisseur de cette manière : Faites une découpe dans le panneau en suivant le modèle fourni avec le modèle TR.
  • Page 8: Connexions Électriques

    (para un nivel de sonido más suave, gire est nécessaire. Contactez votre distributeur agréé ou en sentido horario) l’assistance clientèle de Federal Signal. Les produits Vis de réglage à tête allen (pour un niveau sonore plus faible, tournez dans le sens des défectueux sous garantie seront réparés ou remplacés à...

Table des Matières