3.8
Electrical connection
WARNING: The heat pump's power supply MUST be disconnected before any operation.
Please comply with the following instructions to electrically connect the heat pump.
Step 1:
Detach the electrical side panel with a screwdriver to access the electrical terminal block.
Step 2:
Insert the cable into the heat pump unit by passing it through the opening provided for that purpose.
Step 3:
Connect the power supply cable to the terminal block in accordance with the diagram below.
Carefully close the heat pump panel.
Step 4:
Servo-control of circulating pump
Depending on the type of installation, you can also connect a circulating pump to terminals P
that this operates in tandem with the heat pump.
WARNING: Servo-control of a pump whose power exceeds 5A (1000W) requires the use of a
power relay.
3. Installation
Single phase model
L
N
P
PHASE
PHASE
NEUTRAL
NEUTRE
EARTH
TERRE
PHASE
PHASE
Connect to a filtration
Connecter à la
Connecter à l'alimentation
Connect to power supply
pump or a power
pompe à filtration
230V / 50Hz
230V / 50Hz
ou un relais de puissance
17
P
1
2
NEUTRAL
NEUTRE
relay
and P
so
1
2