5.3.1 - CUT-OUT SWITCH (Only the United States)
This UL version high-pressure washer is equipped with a cut-out switch contained in the power
cable plug.
Said equipment provides extra protection against the risk of electric shock.
When replacing the plug or cable, use the same components including the cut-out device.
5.4 - USE OF CORDS
If an extension cor d is used, make sur e that plug and r eceptacle are of a water -tight type. In
any case they must be raised fr om the ground in order to avoid possible contact with water.
Use only extension cables with the same number of conductors as those of the machine cable,
including the earthing cable, and with a suitable plug/socket for the cable used.
Only use extension cor ds for outdoor use. Said type of cable is marked "Suitable for outdoor
use." Store inside when not in use.
Do not use damaged extension cor ds. Cables should not be located near sour ces of heat or
sharp edges. Always disconnect the plug from the socket before removing the extension cord
from the product. Do not pull the cable to pull the plug out of the outlet. Do not touch the plug
or connections with wet hands.
WARNING
USE OF INADEQUATE
EXTENSION CORDS
MAY CAUSE SAFETY
All manuals and user guides at all-guides.com
HAZARDS
SELECTION TABLE
Extension
Voltage
cord length
220÷240
Up to 20 m
220÷240
From 20 to 50 m
380÷415
Up to 50 m
15
Cord section
mm
2
2,5
4
2,5