Optoelektronische Sensoren
Photoelectric sensors
Détecteurs opto-électroniques
OR18.RL-11157784
OR18.RL-PV1P.7BO
Reflexions-Lichtschranken
Retro-reflective sensors
Barrières réflex
11157784
Baumer Electric AG · CH-8501 Frauenfeld
Phone +41 (0)52 728 1122 · Fax +41 (0)52 728 1144
Canada
Italy
Baumer Inc.
Baumer Italia S.r.l.
CA-Burlington, ON L7M 4B9
IT-20090 Assago, MI
Phone +1 (1)905 335-8444
Phone +39 (0)2 45 70 60 65
China
Singapore
Baumer (China) Co., Ltd.
Baumer (Singapore) Pte. Ltd.
CN-201612 Shanghai
SG-339412 Singapore
Phone +86 (0)21 6768 7095
Phone +65 6396 4131
Denmark
Sweden
Baumer A/S
Baumer A/S
DK-8210 Aarhus V
SE-56133 Huskvarna
Phone +45 (0)8931 7611
Phone +46 (0)36 13 94 30
France
Switzerland
Baumer SAS
Baumer Electric AG
FR-74250 Fillinges
CH-8501 Frauenfeld
Phone +33 (0)450 392 466
Phone +41 (0)52 728 1313
Germany
United Kingdom
Baumer GmbH
Baumer Ltd.
DE-61169 Friedberg
GB-Watchfield, Swindon, SN6 8TZ
Phone +49 (0)6031 60 07 0
Phone +44 (0)1793 783 839
India
USA
Baumer India Private Limited
Baumer Ltd.
IN-411038 Pune
US-Southington, CT 06489
Phone +91 20 2528 6833/34
Phone +1 (1)860 621-2121
www.baumer.com/worldwide
1/2
OR18.RL-PV1P.7BO
Abmessungen
Dimensions
Dimensions
M18 x 1
3
2,8
SW 24
Poti
LED
M12
• Alle Masse in mm
• All dimensions in mm
• Toutes les dimensions en mm
Technische Daten
Grenzreichweite Sn
16 m
Betriebsreichweite Sb
15 m
Betriebsspannungsbe-
10 ... 30 VDC
reich +Vs
1)
Stromaufnahme max.
45 mA
(ohne Last)
Stromaufnahme mittel
35 mA
Spannungsabfall Vd
< 2 VDC
Ansprech- / Abfallzeit
< 0,34 ms
Ausgangsschaltung
PNP Antivalent
Schaltfunktion
Hell- / Dunkel-
schaltung
kurzschlussfest
ja
verpolungsfest
ja
Arbeitstemperatur
-10 ... +55 °C
Schutzart
IP 67
Technische Änderungen vorbehalten
Technical specifications subject to change
Elektrischer Anschluss
BN (1)
+V
WH (2)
light operate
PNP
BK (4)
dark operate
Z
Z
BU (3)
0 V
1)
Class 2, UL 1310, see FAQ
CLASS 1 LASER
PRODUCT
IEC 60825-1/2014
Complies with 21 CFR 1040.10 and
1040.11 except for conformance with
IEC 60825-1 Ed. 3., as described in
Laser Notice No. 56, dated May 8, 2019
• Vor dem Anschliessen des Sensors die Anlage spannungsfrei schalten.
• Disconnect power before connecting the sensor.
• Mettre l`installation hors tension avant le raccordement du détecteur.
Technical data
nominal range Sn
16 m
actual range Sb
15 m
voltage supply range +Vs
10 ... 30 VDC
1)
current consumption max. (no
45 mA
load)
current consumption typ.
35 mA
voltage drop Vd
< 2 VDC
response time / release time
< 0,34 ms
output circuit
PNP comple-
mentary
output function
light / dark
operate
short circuit protection
yes
reverse polarity protection
yes
operating temperature
-10 ... +55 °C
protection class
IP 67
Sous réserve de modifications techniques
Connection diagram
Schéma de raccordement
light operate
BN = Braun/brown/brun
S
WH = Weiss/white/blanc
BK = Schwarz/black/noir
BU = Blau/blue/bleu
Données techniques
Limite de portée Sn
Portée de service Sb
Plage de tension +Vs
1)
Consommation max. (sans charge)
Courant absorbé moyen
Tension résiduelle Vd
Temps d'activation / désactivation
Circuit de sortie
Fonction de commutation
Protégé contre courts-circuits
Protégé contre inversion polarité
Température de fonctionnement
Classe de protection
+Vs
1
2
3
4
0V
dark operate
16 m
15 m
10 ... 30 VDC
45 mA
35 mA
< 2 VDC
< 0,34 ms
PNP complé-
menté
claire/sombre
oui
oui
-10 ... +55 °C
IP 67
2.9.2016