Optoelektronische Sensoren
Photoelectric sensors
Détecteurs opto-électroniques
OR18.RL-11157784
OR18.RL-PV1P.7BO
Reflexions-Lichtschranken
Retro-reflective sensors
Barrières réflex
11157784
Baumer Electric AG · CH-8501 Frauenfeld
Phone +41 (0)52 728 1122 · Fax +41 (0)52 728 1144
Canada
Italy
Baumer Inc.
Baumer Italia S.r.l.
CA-Burlington, ON L7M 4B9
IT-20090 Assago, MI
Phone +1 (1)905 335-8444
Phone +39 (0)2 45 70 60 65
China
Singapore
Baumer (China) Co., Ltd.
Baumer (Singapore) Pte. Ltd.
CN-201612 Shanghai
SG-339412 Singapore
Phone +86 (0)21 6768 7095
Phone +65 6396 4131
Denmark
Sweden
Baumer A/S
Baumer A/S
DK-8210 Aarhus V
SE-56133 Huskvarna
Phone +45 (0)8931 7611
Phone +46 (0)36 13 94 30
France
Switzerland
Baumer SAS
Baumer Electric AG
FR-74250 Fillinges
CH-8501 Frauenfeld
Phone +33 (0)450 392 466
Phone +41 (0)52 728 1313
Germany
United Kingdom
Baumer GmbH
Baumer Ltd.
DE-61169 Friedberg
GB-Watchfield, Swindon, SN6 8TZ
Phone +49 (0)6031 60 07 0
Phone +44 (0)1793 783 839
India
USA
Baumer India Private Limited
Baumer Ltd.
IN-411038 Pune
US-Southington, CT 06489
Phone +91 20 2528 6833/34
Phone +1 (1)860 621-2121
www.baumer.com/worldwide
1/2
OR18.RL-PV1P.7BO
Abmessungen
Dimensions
Dimensions
M18 x 1
3
2,8
SW 24
Poti
LED
M12
• Alle Masse in mm
• All dimensions in mm
• Toutes les dimensions en mm
Technische Daten
Grenzreichweite Sn
16 m
Betriebsreichweite Sb
15 m
Betriebsspannungsbe-
10 ... 30 VDC
reich +Vs
1)
Stromaufnahme max.
45 mA
(ohne Last)
Stromaufnahme mittel
35 mA
Spannungsabfall Vd
< 2 VDC
Ansprech- / Abfallzeit
< 0,34 ms
Ausgangsschaltung
PNP Antivalent
Schaltfunktion
Hell- / Dunkel-
schaltung
kurzschlussfest
ja
verpolungsfest
ja
Arbeitstemperatur
-10 ... +55 °C
Schutzart
IP 67
Technische Änderungen vorbehalten
Technical specifications subject to change
Elektrischer Anschluss
BN (1)
+V
WH (2)
light operate
PNP
BK (4)
dark operate
Z
Z
BU (3)
0 V
1)
Class 2, UL 1310, see FAQ
CLASS 1 LASER
PRODUCT
IEC 60825-1/2014
Complies with 21 CFR 1040.10 and
1040.11 except for conformance with
IEC 60825-1 Ed. 3., as described in
Laser Notice No. 56, dated May 8, 2019
• Vor dem Anschliessen des Sensors die Anlage spannungsfrei schalten.
• Disconnect power before connecting the sensor.
• Mettre l`installation hors tension avant le raccordement du détecteur.
Technical data
nominal range Sn
16 m
actual range Sb
15 m
voltage supply range +Vs
10 ... 30 VDC
1)
current consumption max. (no
45 mA
load)
current consumption typ.
35 mA
voltage drop Vd
< 2 VDC
response time / release time
< 0,34 ms
output circuit
PNP comple-
mentary
output function
light / dark
operate
short circuit protection
yes
reverse polarity protection
yes
operating temperature
-10 ... +55 °C
protection class
IP 67
Sous réserve de modifications techniques
Connection diagram
Schéma de raccordement
light operate
BN = Braun/brown/brun
S
WH = Weiss/white/blanc
BK = Schwarz/black/noir
BU = Blau/blue/bleu
Données techniques
Limite de portée Sn
Portée de service Sb
Plage de tension +Vs
1)
Consommation max. (sans charge)
Courant absorbé moyen
Tension résiduelle Vd
Temps d'activation / désactivation
Circuit de sortie
Fonction de commutation
Protégé contre courts-circuits
Protégé contre inversion polarité
Température de fonctionnement
Classe de protection
+Vs
1
2
3
4
0V
dark operate
16 m
15 m
10 ... 30 VDC
45 mA
35 mA
< 2 VDC
< 0,34 ms
PNP complé-
menté
claire/sombre
oui
oui
-10 ... +55 °C
IP 67
2.9.2016

Publicité

loading

Sommaire des Matières pour Baumer OR18.RL-11157784

  • Page 1 • Vor dem Anschliessen des Sensors die Anlage spannungsfrei schalten. • Disconnect power before connecting the sensor. Baumer Electric AG · CH-8501 Frauenfeld • Mettre l`installation hors tension avant le raccordement du détecteur. Phone +41 (0)52 728 1122 · Fax +41 (0)52 728 1144...
  • Page 2 LED Anzeigen Montage LED indication Mounting Indication LED Montage Output: Power ON LED Die gelbe LED signalisiert, Ausgang ist The yellow LED ON indicates that the La LED jaune allumée indique l’état de la geschaltet output status is closed sortie fermé Output LED Power ON: Grüne LED (Betriebsanzeige)