Turn the main switch (1) to position "1" in order to put the machine under tension.
Observation:
• When starting a single phase machine, the start button has to be turned until the machine runs
at full speed. As long as the start button is turned, the starting capacitor of the machine stays
connected and will get damaged.
• The motors are secured against overloading. If the motor is turned off because of this
protection,
you need to wait until the machine has cooled down, before starting it up again.
• When starting a three phase machine, simply push the white start button (2).
The motor is stopped automatically when the emergency stop button (4) is used.
The machine is equipped with overload protection, and should the motor be shut-off by this
protection, it is necessary to wait for a few minutes untill the overload has cooled down, and resets
itself.