Choose your exhaust installation type
Recommended exhaust installations
Typical installations vent the dryer from the rear of the laundry
center. Other installations are possible.
A
B
C
A. Dryer
B. Rigid metal or flexible metal vent
C. Clamps
D. Wall
Optional exhaust installations
This laundry center can be converted to exhaust out the right or
left side. To convert the laundry center, use Side Exhaust Kit Part
Number 279823. If your laundry center was previously exhausted
from the right or left side, it can be converted to rear exhaust by
using standard offset connections. To cover the hole in the side,
one of the following plug can be added:
692790 (white)
Follow the instructions in the kit to install. Kits are available from
your local Sears store or Sears Service Center.
A
A. Standard rear offset exhaust installation
B. Rear exhaust for offset close clearance connection
C. Left or right side exhaust installation
All manuals and user guides at all-guides.com
Plan Vent System
D
E
F
G
H
E. Elbow
F. Clamps
G. Elbow
H. Exhaust hood
C
B
Alternate installations for close clearances
Venting systems come in many varieties. Select the type best for
your installation. Three close-clearance installations are shown.
Refer to the manufacturer's instructions provided with the vent
system.
A
A. Loop system with standard elbows
B. Loop system with one offset and one standard elbow
C. Vent system with one periscope (2" [5 cm] clearance)
NOTE: The following kits for close clearance alternate
installations are available for purchase. or further information,
please call 1-800-4-MY-HOME
■
Over the Top Installation:
Part Number 26-49900
■
Periscope Installation (For use with dryer vent to wall vent
mismatch):
Part Number 26-49901 - Less than 5" (12.7 cm) mismatch
Part Number 26-49908 - 5" (12.7 cm) to 18" (45.7 cm)
mismatch
Part Number 26-49904 - 18" (45.7 cm) to 29" (73.7 cm)
mismatch
Part Number 26-49905 - 29" (73.7 cm) to 50" (127 cm)
mismatch
Special provisions for mobile home installations
The exhaust vent must be securely fastened to a noncombustible
portion of the mobile home structure and must not terminate
beneath the mobile home. Terminate the exhaust vent outside.
B
C
®