Do not use with the battery compartment
■
open!
The measuring lines must be disconnected
from the measuring circuit during battery
replacement.
A correct display is ensured within the temper-
■
ature range of -10°C to 55°C.
The additionally displayed warning symbol
■
and acoustic signal at voltages > 35 V are
intended only as a warning of potentially fatal
voltages, not for measurement.
Intended Use
DC voltage tests from 4 V to 1400 V, AC voltage
tests from 3 V to 1000 V, polarity, phase sequence
and continuity tests up to 50 Ω plus FI/RCD tests
and resistance measurements tests up to 1999 Ω
can be carried out. Thanks to the rotating spacer,
single-handed operation is possible during voltage
measurement.
Thanks to its high protection class (IP65), Multi-Tester
Pro LCD can be used even under tough operating
conditions.
Any other use is considered an improper use.
The user is liable for damage resulting
from improper use.
10
All manuals and user guides at all-guides.com
Safety Instructions
Check the warning signal for audibility in loud
■
working environments before starting tests.
Replace the batteries immediately if a contin-
■
uous warning signal sounds when switching
on.
In order to protect the device from being dam-
■
aged, remove the batteries if the device is not
in use for a prolonged period of time.
Use only genuine Würth accessories
■
and spare parts.
Technical data
Item
Display
Nominal voltage
range
Input impedance
Frequency display
Rotary field display
Switchable load
Cyclic duration
factor
Continuity test
Resistance measure-
ment
Protection category
Surge voltage
category
Test standard
Power supply
0715 53 175
Backlit LCD
3 ... 1000 V AC (VRMS)
+ -3 digits
4 ... 1400 V DC + -3 digits
285 kΩ
0 ... 1000 Hz
Yes
30 mA at 230 V
30 s on / 240 s off
0 ... 50 Ω
1...1999 Ω +- 5%
IP 65
CAT IV 1000 V
IEC/EN 61243-3
2 x 1.5 V type AAA Micro
Item 0827 111