Neither Bertazzoni nor the dealer can accept any liability for
damage to the oven or personal injury resulting from failure
to observe the correct electrical connection procedures.
Figure 2
IMPORTANT – *Power cord opening for metal cabinets:
Deburr opening to remove rough edges.
RAdIO OR Tv INTeRFeReNCe
Should there be any interference caused by the over the
range microwave to your radio or TV, check that the oven is
on a different electrical circuit, relocate the radio or TV as far
away from the oven as feasible or check position and signal of
receiving antenna.
HOOd exHAUsT dUCT
When the hood is vented to the outside, a hood exhaust duct
is required. All ductwork must be metal; absolutely do not use
plastic duct. Check that all connections are made securely.
Please read the following carefully:
exHAUsT CONNeCTION: The hood exhaust has been
designed to connect to a standard 3-1/4" x 10" rectangular
duct. If round duct is required, a rectangular-to-round adapter
must be used.
ReAR exHAUsT: If a rear or horizontal exhaust is to be
used, care should be taken to align the exhaust with the space
between the studs, or wall should be prepared at the time it is
constructed by leaving enough space between wall studs to
accommodate exhaust.
MAxIMUM dUCT leNgTH: For satisfactory air movement,
the total duct length of 3-1/4" x 10" rectangular or 6" diameter
round duct should not exceed 140 feet.
Elbows, adapters, wall caps, roof caps, etc. present additional
resistance to air flow and are equivalent to a section of straight
duct which is longer than their actual physical size. When
calculating the total length, add the equivalent lengths of all
transitions and adapters plus the length of all straight duct
sections. Figure 3 shows the approximate feet of equivalent
length of some typical ductwork parts. Use the values in
parentheses for calculating air flow resistance equivalent,
which should total less than 140 feet.
*Opening for
Power Cord
Figure 3
TOOls ReCOMMeNded FOR
INsTAllATION
•
Phillips Screwdriver
•
Electric Drill
•
Scissors
•
Saw to cut exhaust opening
(if needed)
INsTAllATION HARdwARe
The INSTALLATION HARDWARE items 1 - 5 are in a small
bag. Items 6 - 9 are packed separately. All items are in a
small carton packed below the oven.
Item
Part Name & Code
WOOD SCREW 5 X 35 MM
1
TOGGLE BOLT WITH NUTS
2
#10 - 24 X 50 MM
TOP CABINET SCREW 5 X 85 MM
3
TAPPING SCREW 4 X 12 MM
4
FLAT WASHER 30 MM DIAMETER
5
6
EXHAUST DAMPER ASSEMBLY
7
8
GREASE FILTER
9
Parts included not shown to common scale.
E3
Model KO30 PRO X
•
Pencil
•
Measure
•
Tape
•
1/2", 5/8" and 3/32" Drill
Bits
REAR CUSHION
SCALE PLATE
qTY
6
4
2
1
2
1
1
2
2