CP 0022, CP 0032, CP 0069
Converting to wet drilling
C
B
Only for CP 0032 and CP 0069
1. Unscrew plug (A) from the water connection.
2. Unscrew plug (B) from the back head.
3. Remove air tube (C) from the back head.
F
E
Only for CP 0032 and CP 0069
1. Assemble the water conversion kit (D) and
connect it to the water connection.
2. Screw in plug (E) into the back head.
3. Place water tube (F) into the back head.
9800 0901 90c | Original instructions
A
D
Safety and operating instructions
Operation
WARNING
Involuntary start
Involuntary start of the machine may cause injury.
Keep your hands away from the start and stop
►
device until you are ready to start the machine.
►
Learn how the machine is switched off in the event
of an emergency.
Stop the machine immediately in all cases of
►
power supply interruption.
Preparations before starting
Check the drilling equipment
♦
Check that all of the drilling equipment is in good
condition.
Check that the impact surface of the drill steel
♦
shank is flat, with no signs of wear.
Make sure that the air inlet and exhaust ports are
♦
free from obstructions.
Check that the flushing holes in the drill steel and
♦
drill bit are not blocked, and that the flushing air
and water flows through without obstruction.
Make sure that the air filter (located in the air
♦
nipple) is clean and not torn or distorted.
♦
Ensure that the fittings are tight and leak-proof.
DANGER
Whipping air hose
A compressed air hose that comes loose can lash
around and cause personal injury or death
Check that the compressed air hose and the
►
connections are not damaged.
►
Check that all compressed air connections are
properly attached.
Blow out the air hose
Every day before using the drill, blow out the air
♦
hose to clear it of accumulated dirt and moisture.
Fill the lubricator with oil
♦
Check that the chuck and insertion tool shank are
always covered with a film of oil.
15