INSTALLATION MANUEL
GALEO
Illuminated Weatherproof Keypad with remote electronics
3. Press B to exit from
the programming mode.
2 beeps are emitted to confi rm that the key-
pad is in stand-by operating mode.
D. ADDING, CHANGING
OR DELETING A USER CODE
Group 1: From address 00 to address 99,
relay output 1
1. Enter the master code twice
(1 2 3 4 5 default value master code).
2 beeps are emitted to confi rm entry
in programming mode.
2. To add a user code, enter the user
location (from 00 to 99).
If the user location is free 1 beep
is emitted, enter the 4 or 5-digit
User code.
3. To Change a User code enter
the user location.
4 beeps are emitted to indicate that
user location is already programmed.
Enter a new 4 or 5-digit code.
A beep is emitted to confi rm the new
user code.
4. To delete a User code enter
the user location.
4 beeps are emitted.
Press 0 0 0 0 0 in 5-digit length code
or 0 0 0 0 in 4-digit length code.
A beep is emitted to confi rm the new
user code.
NOTE: If the Pin code is already programmed
or is identical to the master code,
then 4 beeps are emitted.
Press B to exit from the programming
mode. 2 beeps are emitted to confi rm
that the keypad is in stand-by
operating mode.
E. TIME OUTPUTS
This section allows to program
the illumination time and the Relay
activation time.
1. Enter the master code twice
(1 2 3 4 5 default value master code).
2 beeps are emitted to confi rm
entry in programming mode.
2. Press A0 to program the key-in
keypad time and the keys lit time.
1 beep is emitted. Enter the time in 10th
of second – 10 for 10 seconds up to 99
for 99 seconds the backlighting dims
10 seconds after the last keypress
or switches off after entering a valid code.
Press 00 for permanent illumination keys.
One beep is emitted to validate the time.
3. Press A1 to program relay 1
output time (door release time).
1 beep is emitted. For a latched output
enter the time in seconds – 01 for 1
second up to 99 for 99 seconds.
Press 00 for a toggled output.
One beep is emitted to validate the time.
4. Press B to exit from
programming mode.
2 beeps are emitted to confi rm that the key-
pad is in stand-by operating mode.
4 beeps indicate a data computing error.
F. RESET MASTER CODE
On stand-by operating mode,
put a jumper on P2.
Wait 1 second and then remove
the jumper. One beep is emitted.
The master code is restored
to its default value 1 2 3 4 5 in 5-digit
code and 1 2 3 4 in 4-digit code.
G. CHANGING THE CODE
BY A USER
To authorize a user to modify its own
User code put a jumper on P3
(to disable the feature remove the jumper).
1. Enter the old user code.
The relay is activated and a beep
is emitted.
2. Enter the 2-digit sub master code
(default sub master code A and B).
A beep is emitted to authorise
the modifi cation.
3. Enter the new user code.
2 beeps are emitted to confi rm
the new code.
4. Check the new user code to be sure
of the modifi cation.
cdvi.com
11
cdvigroup.com