Faults - causes and remedies
Fault
The power indicator light
does not light up after
switching on
The automatic circuit
breaker in the fuse box
trips
Oil is dripping out under-
neath the appliance
NOTE
If you cannot resolve the problem with the steps described
►
above, please contact after-sales service.
BEEM - Elements of Lifestyle
All manuals and user guides at all-guides.com
Possible cause
Plug not inserted into
mains socket
Automatic circuit breaker in
fuse box tripped
Rotary knob not in the cor-
rect position
Thermostat is set to
Timer set to "
Too many appliances con-
nected to the same power
circuit.
Appliance defective
Drip tray not inserted
Troubleshooting
Remedy
Insert plug
Switch on the auto-
matic circuit breaker
again
Turn the rotary
knob to the correct
position
Set a higher tem-
"
"
¡
perature
"
Switch on timer
¡
Reduce the number
of appliances on the
power circuit
Contact customer
service
Insert drip tray