Chapter 13
STEP
DESCRIPTION
NO.
01
02
03
04
05
Bypass temperature
06
Bypass hysterese
07
Operation bypass valve
08
Communication
09
Bus address
Central heating +
10
heat recovery
11
Imbalance permissible
12
Fixed imbalance
STEP
DESCRIPTION
NO.
13
Postheater
14
Temperature postheater
15
Selection input 1
16
Minimum voltage input 1
17
Maximum voltage input 1
Conditions
18
switching input 1
Supply fan mode
19
switching input 1
38
All manuals and user guides at all-guides.com
FACTORY SETTING
RENOVENT EXCELLENT
3
50 m
/h
100 m
3
/h
3
200 m
/h
300 m
3
/h
22.0 °C
2.0 °C
0
eBus
0
OFF
ON
3
0 m
/h
FACTORY SETTINGS
RENOVENT EXC. PLUS
0
21.0 °C
OFF
0.0 V
10.0 V
0
5
Renovent Excellent
ADJUSTING RANGE
3
3
0 m
/h or 50 m
/h
50 m
3
/h - 400 m
3
/h
3
3
50 m
/h - 400 m
/h
50 m
3
/h - 400 m
3
/h
15.0°C - 35.0°C
0,0 °C - 5,0 °C
0 (= Automatic)
1 (= Bypass valve closed)
2 (= Bypass valve open)
Ot ( = Opentherm)
eBus
0 - 9 (0 = Master)
OFF (=Central heating+heat recovery off)
ON (= Central heating+heat recovery on)
ON (= imbalance permissible)
3
3
-100 m
/h - 100 m
/h
ADJUSTING RANGE
0 = OFF
1 = Preheater
2 = Postheater
15.0°C to 30.0°C
OFF ( = switching input 1 active)
ON (= 0 - 10 volt input 1 active)
0 volt - 10 volt
0 volt - 10 volt
0 (off)
1 (on)
2 (= On if conditions bypass
3 (= Bypass control)
4 (= Bedroom valve)
0 (= Input fan off)
2 (= Flow rate mode 1)
3 (= Flow rate mode 2)
4 (= Flow rate mode 3)
5 (= Multiple switch 6 (= Maximum
Setting values
Display TEXT +
STAP
5 m
3
/h
3
5 m
/h
5 m
3
/h
0.5 °C BYPASS
0,5 °C BY HYS
BYPASS
OT/BUS
BUSADR
Central heating
+ heat recovery
3
1 m
/h
STEP
HEATER
0.5 °C HEATER
V1
0.5 V
V1 MIN
0.5 V
V1 MAX
CN1
3
/h)
CN1