Chapter 11
The electrical connections of the postheater and the extra preheater are the same; the only difference is that the postheater has an
additional temperature sensor that must be wired to connector X15.
Please refer to the mounting instructions that came with the heater for more extensive information regarding installation of the pos-
theater or the extra preheater.
Parame-
Description
ter
13
Postheater
14
Temperature postheater
32
All manuals and user guides at all-guides.com
Electric connections accessories
Factory
setting
Renovent Excellent
A = Renovent Excellent Plus
B = Plus version control board
C = Heating coil ( 1000W max.)
D = Temperature sensor
E = Maximum safety with manual reset
F = LED maximum safety; lights up when ac-
tivated
G = Cables to be connected by installer
H =
Flow direction through the heater
differs from that through the postheater;
the heating element matches the orienta-
tion of the arrow on that element.
Range
0 = OFF
0
1 = Preheater
2 = Postheater
21°C
15°C - 30°C
C1
= brown
C2
= blue
C3
= green/yellow
C4
= black
C5
= white
E2362-B