Figure 13-3 Schéma de câblage
CAUTION
WIRING DIAGRAM
LBL20413 REV B
68
X3
X5
PC INTERFACE
CONNECTION BOARD
CM 2 PC
CN3
CN3-16
INTERFACE
SHIELD
CN4
CN3-15
CASCADE
RS485
CN3-14
CN3-13
SHIELD
CN3-12
TANK
SENSOR
CN3-11
CN3-10
CN3-9
CN3-8
CN3-7
CN3-6
-
EXTERNAL
10VDC
CONTROL
CN3-5
+
CN1
CN3-4
SHIELD
CN3-3
CN1-10
MOD BUS
RS485
CN3-2
MOD BUS
CN1-2
KIT
CN3-1
SHIELD
CN1-9
GY
CN1-11
CN2-14
CN2-13
W
CN1-3
TANK
TANK
CN2-12
PK
THERMOSTAT
THERMOSTAT
FLOW
CN1-4
SWITCH 1
CN2-11
T
HEX1
CN1-5
CN2-10
BR
SAFETY
CN1-6
SWITCH
OR
CN2-9
CN1-13
HEX2
CN2-8
SAFETY
CN1-14
SWITCH
PK
CN2-7
CN1-12
LOUVER
RD
CN2-6
CN1-15
PROVING
RD
CN2-5
CN1-16
RUNTIME
CN2-4
PR
CN1-8
CONTACTS
PR
CN2-3
CN1-7
ALARM
ALARM
CN2-2
CONTACTS
CONTACTS
CN2-1
CN1-1
CN2
HIGH VOLTAGE SPARK LEAD
LOW GAS
HIGH GAS
PRESSURE SWITCH
PRESSURE 1
FLOW
SWITCH 2
HIGH GAS
PRESSURE 2
BR
OR/BK
CAUTION
HIGH VOLTAGE SPARK LEAD
Notes:
1. All wiring must be installed in accordance with: local, state, provincial and national code requirements per either N.E.C. in USA or C.S.A. in Canada.
2. If any original equipment wire as supplied with the appliance must be replaced, it must be replaced with wire having same wire gauge (AWG) and rated for a
minimum of 105° C. Exceptions: Replacement high vo ltage spark lead and ribbon cables must be purchased from the factory. Use of a non-approved spark lead
or ribbon cables can lead to operational problems which could result in non-repairable damage to the integrated controller or other components.
3. Actual connector block locations may vary from those shown on diagrams. Refer to actual components for proper connector block locations when using
diagrams to troubleshoot unit.
Manuel d'installation et de fonctionnement
LOW VOLTAGE
120 VAC
HIGH VOLTAGE
CM 1 PC INTERFACE
LOUVER
CONTROL
CONTACTS
MODULE 1
R1
RELAY
BOARD
X8
K3
Y
X1-3
K2
X4
K1
ON/OFF
SWITCH
BK
X1-6
X1-5
W
GR
X1-8
X1-1
R
W
G
4 CONDUCTORS
1
2 3
BLOWER
1 2
3
4 5
R
X5-5
T
X5-13
W
X5-6
BK
X5-12
PK
OR
X5-4
X6-2
GY
BL
X5-10
X6-7
AUTO RESET LIMIT
GY
X6-6
BL
X5-7
PR
X5-14
W
X6-1
X5-3
BK
X5-8
RD
T
X5-1
X6-9
X5-2
X6-5
W
OR/BK
Y
X5-9
X6-10
X6-8
PR
BK
X3-2
X2-2
X2-1
Y
RD
X3-4
PR
X3-1
RD
X3-3
W/RD
X1-7
BLOCKED
DRAIN
CONTROL
MODULE 2
X8
GY
X1-3
X4
W
X1-5
BK
X1-6
GR
X1-8
RD
X1-1
R W
G
1
2 3
BLOWER
1 2
3
4 5
X6-5
RD
X5-5
T/BK
X5-13
X6-9
W
X5-6
X6-10
BK
X5-12
OR/BK
X5-4
GR/BK
X5-10
AUTO RESET LIMIT
BL/BK
X5-7
PR/BK
X5-14
PK
X5-3
BK/RD
X5-8
RD/BK
X5-1
W/BK
X5-2
X5-9
Y/BK
X6-8
PR
X3-2
BK
X2-2
RD
X2-1
X3-4
Y
PR
X3-1
G
SPARK
ROD
RD
X3-3
X1-7
RD/W
BOX DEPICTS
OPTIONAL ITEMS
R2
JUNCTION
BOX
LOUVER
PR
HW1
BR
PUMP
BR
HW2
BR
PUMP
GND
GND
L
120V SUPPLY
GND
N
GND
LOUVER
LOUVER
RELAY 1
RELAY 1
FLAP
VALVE
APS
DOOR TEMP
O-TEMP
HEX1
SW
HEX SW
TSTAT
HI-LIMIT
INLET
SENSOR
OUTLET
SENSOR
FLUE
SENSOR
GAS
VALVE
G
SPARK
ROD
FLAME ROD
LOUVER
RELAY 2
FLAP VALVE
APS
O-TEMP
HEX2
DOOR TEMP
TSTAT
SW
HEX SW
HI-LIMIT
INLET
SENSOR
OUTLET
SENSOR
FLUE
SENSOR
GAS
VALVE
FLAME ROD