16
Other technical data
TOTAL POW‐
ER:
Electric supply:
Appliance cate‐
gory:
Gas connec‐
tion:
Appliance
class:
Gas burners for LPG G30/G31 30/30 mbar
BURNER
Multi Crown
Rapid
Semi-rapid
Auxiliary
Gas burners for NATURAL GAS G20 20 mbar
BURNER
Multi Crown
Rapid
Semi-rapid
Auxiliary
ENVIRONMENTAL CONCERNS
Recycle materials with the symbol
the packaging in relevant containers to
recycle it. Help protect the environment
and human health by recycling waste of
electrical and electronic appliances. Do
All manuals and user guides at all-guides.com
G30/G31 (3B/P) 30/30
Gas original:
mbar
Gas replace‐
G20 (2H) 20 mbar
ment:
220-240 V ~ 50-60 Hz
II2H3B/P
G 1/2"
3
NORMAL
MINIMUM
POWER kW
POWER kW
3,65
1,2
2,85
0,95
1,85
0,6
1,0
0,33
NORMAL POWER
kW
4,0
2,95
1,85
1,0
. Put
INJECTOR
MARK
095
86
71
50
MINIMUM POWER
kW
1,4
0,75
0,6
0,33
not dispose of appliances marked with the
symbol
with the household waste.
Return the product to your local recycling
facility or contact your municipal office.
813 g/h
11,65 kW
NOMINAL GAS
FLOW g/h
265
207
134
73
INJECTOR MARK
146
119°
92
70