TECHNICAL DATA

11. Technical data
Part number
Electrical data
Phases
Voltage
Wattage
Amperage draw
Min. recommended circuit breaker size
2
Min. recommended wire size
(copper)
Connections
3
Water connection
Application limits
Max. permissible pressure
Recommended inlet temperature
Minimum water flow to activate unit
* AQM 2-1 is internally restricted to 0.32 gpm (1.2 l/min).
1 Nominal mains voltage is 110–120 V and 220–240 V.
2 This is our recommendation for overcurrent protection sized at 100% of load. Check local codes for compliance if necessary.
Tankless water heater are considered a non-continuous load.
3 Copper must be used. Conductors should be sized to maintain a voltage drop of less than 3% under load.
4 For use with cold water supply only.
WWW.APTANKLESS.COM
AQM 2-1
*
AQM 2.5-1
612431
612432
1 - 50/60 Hz
120 V
120 V
1.8 kW
2.4 kW
15 A
20 A
1
15 A
20 A
14 AWG
12 AWG
⅜˝ O.D. flex connector or ⅜˝ compression fitting
150 psi (10 bar)
41–77 °F (5–25 °C)
0.21 gpm
0.4 gpm
(0.8 l/m)
(1.5 l/m)
AQM 3-1
AQM 3.5-1
612433
612434
120 V
120 V
3.0 kW
3.5 kW
25 A
29 A
25 A
30 A
10 AWG
10 AWG
0.4 gpm
0.4 gpm
(1.5 l/m)
(1.5 l/m)
AQM ELECTRIC TANKLESS WATER HEATERS |
AQM 4-2
AQM 6-2
612435
612436
240 V
208 V
240 V
208 V
3.5 kW
2.6 kW
5.7 kW
4.3 kW
14.6 A
12.5 A
23.8 A
20.6 A
15 A
15 A
25 A
25 A
14 AWG
10 AWG
0.4 gpm
0.77 gpm
(1.5 l/m)
(2.9 l/m)
17

Publicité