The red LED DL1 indicates the activation of inputs according to the legend hereunder:
STOP
PHOT
DOWN
UP
DOWN+UP
By flashing slowly, the red LED DL1 also indicates that the unit is powered.
The green LED and the output SCA (DIP 4OFF) indicate the direction of the movement of the motor and
the status of the bollard, as follows:
Lowering bollard
Raising bollard
Bollard in lower position (without TCA) ON with fixed light /N.C. contact
Bollard in lower position (with TCA)
Bollard in raised position
HY.TERM
Adjustable thermostat for cold places
Connect to the control panel to HY.TERM input as indicated (Fig. 2) . The thermostat is supplied into a
waterproof box for outdoor installation and it is equipped with 1m cable.
If the temperature drops below the set value the control panel makes the motor to keep the oil warm. We
suggest to set the HY.TERM at a temperature of -5°C.
HY.BUZZ
Acustic warning device . Connect the device by means of the power circuit AC/DC supplied , as indicated
in Fig.3
The acustic warning device will indicate the raising of the bollard (DIP 4)
The acustic device cannot be installed outdoor , we suggest to locate it into the control panel plastic box
or into another plastic box with the same IP rate.
HY.VLL / HY.VLV
Electronic circuit for the control of the LED light (HY.LED) or (HY. VA) Electrovalve for automatic lowering
in case of power failure.
Connect the circuit as indicate ( Fig.4)
The Leds indicate the status of the bollard:
During the raising cycle : fast flashing
If the product must be dismantled, it must be disposed according to regulations in force regarding the
differentiated waste disposal and the recycling of components (metals, plastics, electric cables, etc..). For
this operation it is advisable to call your installer or a specialised company.
14
on with fixed light
rapid flashing
1 flash with 2-second interval
2 flashes with 2-second interval
3 flashes with 2-second interval
1 flash /1 relay switching with 1 sec. delay
2 flashes/ 2 relay switching with 1 sec. delay
2 flashes/ 2 relay swicthing per sec.
LED OFF/ N.O. contact
LED DIAGNOSTICS
OPTIONALS
WASTE DISPOSAL