With all DIPs on ON, the control unit switches to SERVICE MAN mode.
The DOWN/UP push-buttons must be kept pressed during operation. The opening of the STOP input
stops the motor.
The contemporary pressure of DOWN/UP stops the motor.
Immediately after putting the DPI1 in ON position the red led light DL1 indicates the activation or the
deactivation of the preflashing
Con il DIP2 è possibile attivare o disattivare la funzione prelampeggio.
The DIP 2 allows to activate or deactivate the preflashing function.
DIP2 ON: preflashing activated , the lights start flashing 5 sec. before the raising cycle starts
DIP2 OFF: preflashing deactivated.
The HY.CELL control unit is equipped with a built-in radio module for the fixed or roll-on code of remote
controls, with 433.92MHz frequency.
To use a remote control, it is first necessary to store its code in memory. The memorisation procedure is
described hereunder. The device is able to store up to 64 different codes in memory.
By pressing P1, the control unit enters the radio learning phase: DL1 red LED flashes 1 time per second,
awaiting the key to the matched to the DOWN function;
When the key is stored in memory, exit from the programming mode;
Pushing twice P1 the red led light DL1 flashes twice per second waiting for the assignment of the push
button to be assigned to UP function.
When the key to be matched is memorised, exit from the programming mode.
Pushing three times P1 , the red LED light DL1 flashes 3 times per second waiting for the assignment of
the push button to be assigned to STEP BY STEP function.
Once assigned the push button to the relevant functions the programming is completed.
In case you don't need to memorize any transmitter, keep the button P1 pressed until the red light DL1
start flashing again in the way that indicates the presence of network (see diagnostics LED pag.7)
To reset the memory of the receiver, press and keep P1 and P2 keys pressed for around 10 seconds
(during this period of time, both DL1 and DL2 flash rapidly).
After 10 seconds, when the two LEDs are switched on with fixed light, release the push-buttons.
When the LEDs switch back again to the original configuration, the control unit has completed the memory
reset.
NOTE:
The transmitters are memorised on an EPROM memory (U2), which can be extracted from the control unit
and inserted in a new HY.CELL control unit should a replacement is required.
For safety reasons, the transmitters can be stored in memory during the raising/lowering of the motor.
If the transmitter code is already stored in the receiver, the remote radio learning can be carried out
(without accessing the control unit).
IMPORTANT: The procedure should be carried out with gate in the lowering phase, during the TCA
dwell time.
Proceed as follows:
1 Press the hidden key of the transmitter, the code of which has already been stored in memory.
2 Within 5 seconds, press the already memorised transmitter key corresponding to the channel to be
matched to the new transmitter. The flashing light switches on.
3 Within 10 seconds, press the hidden key of the new transmitter.
4 Within 5 seconds, press the key of the new transmitter to be matched to the channel selected at item 2.
The flashing light switches off.
5 The receiver stores the new transmitter code and exits from the programming mode immediately.
SERVICE MAN MODE
PRE-WARNING ACTIVATION/DEACTIVATION (DIP2:ON)
RADIO SELF-LEARNING
TRANSMITTER REMOTE LEARNING